observe all safety instructions. Wear a
breathing mask when there is a risk of inha-
ling spray materials. Carefully check the
function of the breathing mask before put-
ting it on.
Always wear goggles when handling the
compressor. Never direct the nozzle of an
accessory towards your body or towards
another person.
Do not try to adjust the pressure switch or
the drain valve underneath the pressure
switch cover.
Remove daily the liquid from the tank in
order to avoid corrosion.
Pull the ring on the safety valve to make
sure it works well.
Keep the compressor at least 300 mm away
from the wall in order to ensure sufficient
venting for the cooling.
Before you transport the compressor, drain
the compressed air from the tank and secu-
re the machine safely.
Protect the air hose and the cable set from
damage. Regularly examine the compo-
nents for weak and worn spots, and replace
them in case of need.
Do not use an extension cable for this pro-
The machine meets all valid EC machine
guidelines.
Only use indoors . Prohibited to use out-
doors.
The machine must only be used in tech-
nically perfect condition and conscious
of the risks, in accordance with its desi-
gnated use and the instructions set out in
the operating manual.
Any functional disorders, especially those
affecting the safety of the machine, must be
D GB
rectified immediately.
The safety, working and maintenance
instructions of the manufacturer as well as
The machine has been built using modern
technology in accordance with recognized
safety rules. Some remaining hazards, how-
ever, may still exist.
Noise can be a health hazard. If the permit-
ted noise level is exceeded when working,
be sure to wear ear protection.
The use of incorrect or damaged mains
cables can lead to injuries caused by elec-
tricity.
Even when all safety measures are taken,
some remaining hazards which are not yet
evident may still exist.
Remaining hazards can be minimized by
following the instructions given in the chap-
ters „Safety notes" and „Use as authorized"
as well as in the entire operating manual.
Due to modern series production it is impro-
bable that your compressor has any defects or
that a part is missing. Should you note a fault,
however, do not switch the machine on before
the parts are replaced or the fault has been re-
medied. Not observing this instruction can lead
to serious injuries.
duct. Use instead an additional air hose in
order to avoid a drop in power and a pos-
sible motor damage. The use of an extensi-
on cable makes the warranty invalid.
After a long period of work, the outer metal
parts can get hot.
Press the ON/OFF switch to switch off the
compressor. Only then cut the mains supply
or pull the power supply plug.
Before working with the compressor, check
the oil level. It must be near the red circle
as shown on the display.
Attention: Oil must be filled in before the
initial put ting into operation.
After using the compressor, press the ON/
OFF switch, cut off the mains supply, and
open the drain valve in order to reduce the
pressure.
Do not try to remove a part from the machi-
ne while it is pressurized.
Make sure the lubrication oil is clean and
always available in sufficient quantity.
Change the oil according to the instructions
given in the chapter „Maintenance" of this
manual.
Wear safety gears including goggles or
a screen, ear protection, breathing mask
Use as authorized
the dimensions given in the chapter „Tech-
nical data" must be adhered to.
The relevant accident prevention regula-
tions and other, generally recognized
safety-technical rules must also be adhered
to.
The machine may only be used, maintai-
ned, and operated by persons familiar with
it and instructed in its operation and proce-
dures.
Arbitrary alterations to the machine release
the manufacturer from all responsibility for
any resulting damages.

Remaining hazards

Even when all safety measures are taken, it is
not possible to exclude all remaining hazards.
Due to the construction of the machine, the
following risks can occur:
Injury of the lung when no breathing mask
is worn.
Injury of the ear when no ear protection is
worn.
Injury of the eyes when no efficient goggles
(or protective screen) are worn.
Warning:
If an air hose is broken off or damaged, the air
input on the compressor must be switched off.
A broken air hose that is not supported, is extre-
mely dangerous and can quickly start to rotate,
hitting people or blowing foreign bodies
Unpacking
12
and protective clothing.
After connection to the mains and switching
on, the machine starts automatically.
Air escaping from the compressor may not
be inhaled.
Check the pressure control valve daily befo
re starting work.
Drain humidity from the tank. Avoid tank
corrosion.
Cut off the mains supply, remove the power
supply plug, and relieve the pressure before
starting maintenance work.
Wear goggles.
Wear ear protection.
Wear a breathing mask.
Never direct the output air from the compressor
towards a part of the body or a person. Never try
to block the air escape with your finger or a part
of your body.
The machine may only be used with original
accessories and original tools supplied by
the manufacturer. Any other use exceeds
authorization. The manufacturer is not
responsible for any damages resulting from
unauthorized use; risk is the sole responsi-
bility of the operator.
in the air.
Do not try to catch the hose. Instead, immedia-
tely remove all spectators from the dangerous
area, cut off the air input, and switch the ma-
chine off by pressing the ON/OFF switch. Then
remove the hose from the compressor.