• Please read the notes in the operating
instructions on the topic of "mainte-
nance and cleaning". Any measures
above and beyond these, particularly
opening the equipment, are to be car-
ried out by an electrician. In the case
of repairs, always contact our service
centre.
Electrical safety:
• After erection, the mains plug must be
freely accessible when the equipment
is in operation.
• Before operating your new pump, have
a specialist check:
• The earthing, the protective multi-
ple earthing; the residual current cir-
cuit breaking must be compliant with
the safety regulations of the energy
supply company and function with-
out fault,
• The protection of the electrical plug
connections from the wet.
• If there is a risk of flooding, fix the
plug connections in an area that is
safe from flooding..
• Ensure that the mains voltage matches
the specifications on the rating plate.
• The electrical installation shall be ac-
cording to national wiring rules.
• Connect the equipment only to a sock-
et with a residual current protection de-
vice (residual current circuit breaker)
with a rated current of not more than 30
mA; minimum fuse 6 amperes.
• Before each use, check the equipment,
cable and plug for damage. Defective
cables are not to be repaired, but rather
replaced by new ones. Have any dam-
age to your equipment repaired by a
specialist.
26 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
• If the power cable for this equipment
is damaged, it must be replaced by
the manufacturer, a customer service
agent of the same or a similarly quali-
fied person in order to prevent hazards.
• Do not pull the plug from the socket by
the cable. Protect the cable from heat,
oil and sharp edges.
• Do not carry or fix the equipment by the
cable.
• Use only extension cables that are pro-
tected from spray water and designed
for outdoor use. Always fully unroll a
cable drum before use. Check the ca-
ble for damage.
• Before any work on the equipment, dur-
ing work breaks and in the case of non-
use, remove the plug from the socket.
• The cross-section of mains connec-
tion lines must be no smaller than rub-
ber hose lines with the designation
H07RN-F. The line must be 10 m long.
The strand cross-section of the exten-
sion cable must be at least 1.5 mm
Inside the pump, lubricants are used
which may contaminate the liquids being
discharged in case of any improper oper-
ation or damage of the device.

6. Technical data

Dimensions L x
B x H
Mains connection
Power rating
Max. delivery rate
.
2
176 x 179 x 326
mm
220 - 240V~
50 Hz
750 W
20000 l/h