Herunterladen Inhalt Inhalt Diese Seite drucken

Resetting To The Initial State - HomeMatic HM-CC-SCD Bedienungsanleitung

Funk-kohlendioxid sensor
Vorschau ausblenden Andere Handbücher für HM-CC-SCD:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7
The device can be reset to the initial state. Doing this deletes all
information relating to taught-in components.
To reset, proceed as follows:
• Press and hold down the teach-in button (for more than 4
seconds). The device LED starts to slowly flash red. If you wish
to abort the reset at this point, wait 15 seconds. The slow red
flashing will stop.
• To reset the device, press and hold down the teach-in button
again (for more than 4 seconds). The LED will now start to flash
red faster. Release the teach-in button to complete the reset
procedure; the LED lights up continuously for around three
seconds to confirm that the reset has been successful.
Possible error messages: The following error can only occur if
been held down for 5 seconds, but lights up continuously
instead, the device cannot be reset. In this case, coding is
activated using a system security key that differs from the one
supplied with the product. To reset the sensor, you will have to
use the configuration software for resetting the central control
unit. The procedure to follow is described in the manual for the
central control unit software.
Downloaded from
www.Manualslib.com

Resetting to the initial state

you have a central control unit to which you have
taught-in the device.
If the LED does not start to flash when the button has
manuals search engine
19

Werbung

Kapitel

Inhaltsverzeichnis
loading