Fault phenomenon
7. Display ERR2
8. Display ERR3
9. Display ERR4
10. Display ERR5
11. Display ERR7
12. Display ERR8
13. Display ERR78
14. Only 00-00 is displayed,
and the value is not displayed
52
AE2021
Fault causes
1. Check the computer board for being damaged
2. Wheels are not installed
3. Install only one rim, but not install the tire
4. The spindle matcher is not installed tightly
5. The wheel is not installed correctly and is not locked
6. The belt is too loose or too tight
7. The screw rod is stripped and the wheel is not
fastened
8. The half nut is stripped and the wheel is not tightened.
1. Check the computer board for being damaged
2. The wheel unbalance is too serious to be calculated
1. Check the computer board for being damaged
2. If it is rotated negatively, the phase lines are
connected incorrectly
3. If it is rotated positively, there is something wrong
with the photoelectric sensor
1. Check the computer board for being damaged
2. The protective cover of wheels is not put down
3. Check the limit switch for being damaged
1. Check the computer board for being damaged
2. The stored data is lost
1. Check the computer board for being damaged
2. Check the power panel for being damaged
3. Do not add 100 g lead when conducting self-
calibration.
4. The lead of piezoelectric sensor is broken
5. The piezoelectric sensor is broken
1. The screw of width ruler potentiometer is loose and
the data roller is disordered after pulling a and d
1. The lead of piezoelectric sensor is broken or in poor
contact
2. The stored data is lost
3. Check the computer board for damage
中文
EN
DE
RU
KO
Troubleshooting methods
1. Replace
2. Install the wheel and try again
3. Install the tire
4. Re-tighten the bolt
5. Choose the proper cone and install it
correctly
6. Re-adjust it
7. Replace it and reinstall the wheels
8. Replace it and reinstall the wheels
1. Replace
2. Replace the wheel and try again or
conduct the self-calibration again
1. Replace
2. Adjust the phase lines
3. Adjust the position again or replace it
1. Replace
2. Put the protective cover down
3. Replace
1. Replace
2. Input the parameters and recalibrate it
1. Replace
2. Replace
3. Apply a 100g lead
4. Connect the connecting wire properly
5. Replace
1. Re-adjust the potentiometer, tighten the
screws, and carry out self-calibration of
the measuring tape
1.Reconnect
2.Re-correct memory value
3. Replace