Chapter VII Common Troubleshooting Methods

Fault phenomenon
1. Turn on the power switch
2. No display after starting up
3. The display is normal after
startup, while the motor does
not rotate when pressing the
start key.
4. The motor keeps rotating
after startup
5. No brake after startup
6. Display ERR1 after startup
AE2021
Fault causes
1. Check the motor for damp or electric leakage
2. Check the power board transformer for leakage
3. Check the brake resistance for leakage
4. Check whether the chassis is connected to the
grounding electrode line
1. Check the external circuit for being energized
2. Check the power switch for being damaged
3. Check the fuse on the power board for being loose or
burning out
4. The power supply leads of computer board are broken
5. Check the power panel for being damaged
6. Check the computer board for being damaged
9. Check the line between the main computer board and
the display board for being connected properly
1. Check the power panel for being damaged
2. Check the computer board for being damaged
3. Check the motor for being damaged
4. Check the motor capacitance for being damaged
5. Check the keyboard plate for being damaged
6. Check the motor wire on the power board or the inner
wire of the motor junction box for being loose
1. Check the computer board for being damaged
2. Check the power panel for being damaged
3. Check the keyboard plate for being damaged and the
position of PV board for being moved
1. Check the power panel for being damaged
2. Check the computer board for being damaged
3.Check the brake resistance for being damaged
1. Check the power panel for being damaged
2. Check the computer board for being damaged
3. Check the connecting wire of the position sensor for
being loose or the position sensor for being damaged.
中文
EN
DE
RU
KO
Troubleshooting methods
1. Dry or replace
2. Replace
3. Replace
4. Connect the grounding electrode line
properly
1. Use multimeter to measure
2. Replace
3. Tighten replace it
4. Connect the connecting wire properly
5. Replace
6. Replace
9. Reconnect the connecting wire properly
1. Replace
2. Replace
3. Replace
4. Replace
5. Replace
6. Fasten it
1. Replace
2. Replace
3.Replace / adjust the position of the PV
board.
1. Replace
2. Replace
3. Replace
1. Replace
2. Replace
3. Re-weld or replace
PT
JA
ES