5.6 After the tire stops, slowly turn the tire by hand until all
unbalance indicators are on.
5.7 At this point, add 100 g of lead inside the tire at the position
of 12 O 'clock, and press [START] to start the motor for the third
time.
5.8 Note: The 12 O 'clock position for adding the lead shall be
accurate. It seriously affects the correctness of the unbalance
position. After the tire stops, if [CAL] [End] is displayed, the
calibration is completed. If [Err] [-*-] is displayed, it means
calibration in progress.