5.3

Checking drive belt

Under standard conditions, for which the adsorption compressed air dryer is designed, the
adsorbent has a minimum service life of three years before it loses its moisture-adsorbing
properties. The following steps should be carried out to change the dryer:
• Ensure that the towers are not under pressure and disconnect the dryer from the system.
• Unscrew the bleed plug.
• Fully remove the adsorbent from the towers.
• Screw on the bleed plug.
• Unscrew the filling plug.
• Fill both towers with original adsorbent, as per table 2.1
• Screw on the filling plug.
• Carry out the start-up procedure as for the first start-up, as per point 4.2.
COMPRAG ADX-F-PDP series
Deterioration of adsorbent can lead to reduced performance of
the air dryer. If you are unable to monitor the quality of dried air,
then you should change the adsorbent every 3 years.