Deleting the limit positions of B-Tronic tubular
drives
Attention
When one or both of the limit positions are deleted, all the
other set functions (e.g. intermediate position) are deleted
as well.
Once set, the limit positions can only be deleted using mas-
ter mode. Deleted limit positions are displayed on the limit
position status indicator.
Deleting individual limit positions
Put the transmitter into master mode.
Select the tubular drive by pressing the
firms.
All the following settings will then only be executed for this device.
5s
62 - en
button until the tubular drive con-
Open/close to the limit position to be deleted.
Press the programming button and, within the
next 1 second, press the STOP button at the same
time and hold the two buttons down for 5 seconds.
▻ The receiver confirms.
► The limit position is now deleted.