Upper point to lower point

Put the transmitter into master mode.
Select the tubular drive by pressing the
firms.
All the following settings will then only be executed for this device.
There is no shading solution length adjustment with this limit
position setting.
60 - en
button until the tubular drive con-
Open to the desired upper limit position.
Press the programming button and, within 1
second, also press the UP button and hold the two
buttons down.
▻ The receiver confirms.
Then close to the desired lower limit position.
Press the programming button and, within 1
second, also press the DOWN button and hold the
two buttons down.
▻ The receiver confirms.
► The limit positions are now set.