This manual has been prepared to enable a correct installation, regulation and maintenance of the appliance; it is therefore of
fundamental importance that :
- the warnings contained in this booklet are read carefully as they supply essential indications regarding the safety of the installation,
use and maintenance.
- This manual and the wiring diagram must be stored with care and made available to the operator for any future consultation.
- The appliance must be installed, tested and serviced by qualified personnel in possession of the legal qualifications.
- The constructor declines all responsibility with invalidity of the warranty in the event of electrical and/or mechanical modifications.
Any adjustment whatsoever not expressly authorized and in disrespect of this manual invalidate the warranty.
- Observe all existing local regulations at the time of installation.
- Verify that the mains line characteristics are conform to the data given on the serial plate of the appliance.
- The packing materials (plastic bags, polystyrene, nails, etc.) as potential hazards, must be kept out of the reach of children and
properly recycled of according to existing local regulations.
- The appliance has been designed and constructed for the conservation of foodstuffs and should therefore be destined to this sole
purpose for which it has been expressly conceived. Any use whatsoever other this specific purpose does not commit the constructor in
any way whatsoever.
- Shutdown the appliance in the event of breakdown or malfunctions.
- For eventual repairs contact exclusively the service centers authorized by the constructor and request the use of original spare parts.
- If in doubt do not use the appliance and contact professionally qualified personnel. The disrespect of the above conditions could risk
the safety of the appliance.
The appliances are designed for indoor installation.
- Check that the floor is capable of supporting the weight of the appliance and that it is level.
- Respect the working spaces. The choice of the appliance's position is of fundamental importance for it to work properly.
The appliances require a minimum space to operate and serving.
It must be installed as far as possible from any heat sources.
- Ensure that there is a clearance of at least 50 cm. between the ceiling or other overhead cover and the top of the appliance, to
guarantee adequate air circulation.
- The refrigerators are shipped in appropriate protective packing. On arrival, check that the appliance has not incurred transport
damage and that it is complete according to the order.
Modello - Model
Temperatura di esercizio / Temperature Range
Temperatura ambiente / Environment temp.
Funzionamento / Running
Dimensioni esterne / Ext. dimensions
Capacità lorda / Gross volume
Dimensioni interne / Int. dimensions
Spessore isolamento / Insulation thickness
Tipo di refrigerante / Gas
Potenza frigorifera / Refrigeration power
Potenza elettrica installata / Installed electrical power
Tensione di alimentazione / Power
Peso netto / Net weight
Peso lordo all'imballo / Gross weight (with package)
10 / 14
GENERAL NOTICES
ROLL IN TOP LINE TB22
°C
°C
mm
Lt.
mm
mm
Watt
Watt
Kg
Kg
*H01
-2/+8
+43 Max.
Ventilato/Ventilated
Ventilato/Ventilated
880x1060x2300 H
880x1060x2300 H
1170
700x900x1860 H
700x900x1860 H
70
R404A
585 A -10°
682
230V / 1 / 50
180
210
*L01
-15/-24
+43 Max.
Ventilato/Ventilated
880x1060x2300 H
1170
700x900x1860 H
70
R404A
587 A -30°
726
230V / 1 / 50
230V / 1 / 50
210
235
*W01
+95
+43 Max.
1170
70
.///
.///
2100
150
185