Technical description
6.2

Status indications

Designation
Red LED
Green LED
Blue LEDs
Meaning of the blue LEDs (mode 1 and 2)
1
2
U
14 V
4
3
2
1
Key to the figure:
LED status
14
Description
Flashing: The polarity is incorrect, or the battery voltage is less than
9 V.
Constantly lit: The connection to the battery was disconnected
during the charging process.
Constantly lit: Mode 1 or mode 3 is active.
Flashing: Mode 2 is active.
In mode 1 and mode 2, the LEDs indicate the phase in which the
battery charger is currently operating (see the following table).
The LEDs flash in succession when the battery charger is operating
in wait mode (the mains voltage is connected but the battery is not
connected).
The LEDs flash simultaneously when the battery charger is ready for
use (mains voltage is connected, battery is connected, button has
not been pressed).
3
4
Mode 2
14,4 V
Mode 1
Meaning
Off
Flashing
Constant glow
PerfectCharge MCP1204/1207
5
6
7
14,7 V
13,8 V
8
14,4 V
12,8 V
t