DAC basic/classic
Control voltage for external actuators:
Voltage when idle
Voltage when under load
Power
Load current
Max. load current
Anzahl Ein- und Ausgänge DAC
Digital-inputs
Analog-inputs
LED-outputs
Digital-outputs
Digital-outputs
PWM-outputs
Anzahl Ein- und Ausgänge DAC
Digital-inputs
Analog-inputs
LED-outputs
Digital-outputs
Digital-outputs
PWM-outputs
Warning: The total load currents of all actuators switched on at the same time
(magnets, magnet valves) must not exceed 3 A permanently.
Control unit dimensions
Downloaded from
www.Manualslib.com
basic
classic
manuals search engine
[V]
25 Gs
[V]
25 Gs when I = 2.9A
[W]
[A]
3
[A]
9, short-term
[24V]
7
[3,3V]
1
[24V/max.30mA]
3
[24V/max. 0,5A]
4
[24V/max. 2A]
1
[24V/max. 2A]
4
[24V]
16
[3,3V]
2
[24V/max.30mA]
6
[24V/max. 0,5A]
8
[24V/max. 2A]
1
[24V/max. 2A]
5
24
Technical information
96 (225, short-term)