12.9
L
C
t
01 00 0
t
01 01 0
t
01 02 0
t
01 11 0
t
01 12 0
t
01 13 0,0
t
01 20 0
Thread clamp function ON: Press
The thread clamp mode can be selected with parameter t 01 00.
© 2010 Dürkopp Adler AG
Downloaded from
www.Manualslib.com
Thread clamp and sewing foot pressure reduction
P
Min
Max
Unit
4
-
359
°
359
°
359
°
time lag °
10,0
%
3
-
manuals search engine
Description
Thread clamp mode
0 = on switching angle FK = t0101,
out switching angle
FK = t0102,
Without FL;
1 = on switching angle FK = 108°,
out switching angle FK = 268°,
Without FL;
2 = on switching angle FK = 49°,
out switching angle FK = 110°,
Without FL;
3 = on switching angle FK = 49°,
out switching angle FK = 190°,
Without FL;
4 = on switching angle FK = 108°,
out switching angle FK 268°,
on switching angle FL = 108°,
out switching angle FL = 154°;
5 = on switching angle FK = 108°,
out switching angle FK = 268°,
on switching angle FL = 44°,
out switching angle FL = 154°;
6 = on switching angle FK = 30°,
out switching angle FK = 200°,
on switching angle FL = 50°,
out switching angle FL = 100°;
7 = Without FK,
on switching angle FL = t0111,
out switching angle FL = t0112;
8 = on switching angle FK = t0101,
out switching angle FK = t0102,
on switching angle FL = t0111,
out switching angle FL = t0112
Thread clamp power on angle
Thread clamp power off angle
Sewing foot elevation power on angle
Sewing foot elevation power off angle
Duty cycle of sewing foot lifting at mode 4-8
Thread clamp options
0 = Thread clamp only at start of seam:
1 = Thread clamp at start of seam and at turn back position;
2 = FK at start of seam and with sewing foot elevation;
3 = FK at start of seam, return position and with sewing foot
elevation;
button. LED on
53
Setting the basic functions