6
6.1
Rated values:
Voltage
Frequency
Current (control unit)
Power (output)
Speed
Torque
Motor moment of inertia
(without belt disc)
Operating mode
Type of protection
Insulation class
Limits:
Rated voltage range
Speed
Torque
Power
Moment of inertia
of the machine, reduced
on the motor shaft
Operating conditions:
Ambient temperature
Ambient temperature (average over 24h)
Humidity (relative)
© 2010 Dürkopp Adler AG
Downloaded from
www.Manualslib.com
Technical information
Technical data
manuals search engine
(U
) [V]
230, monophase
N
(f
) [Hz]
50/60
N
[A]
1.6
(P
) [W]
375
2
(n
) [1/min]
4000
n
(M
) [N
]
0.63
n
m
(J
) [kgcm²]
0.5
mot
S5 (40% ED at ts = 2.5 s)
Intermittent service with electrical braking,
relative power on time 40%, run time 2.5 s
IP40
L
[V]
190 - 240 + 20 %/- 10%
monophase
(n
) [1/min]
max
(M
, short-term) [Nm] 3.5
max
(P2
, short-term) [W] 1500
max
(J
) [kg cm²]
mach
[°C]
+ 5 - 45
[°C]
< 35
85% at 30 °C
23
Technical information
6000
4.5