Herunterladen Inhalt Inhalt Diese Seite drucken

Beninca YAK 20 OM Bedienungsanleitung Seite 26

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 30
PSo
The torque applied to the motor during braking in the closing phase is adjusted.*
PSC
The torque applied to the motor during braking in the opening phase is adjusted *
The trigger time of the anti-crash device (Encoder) is adjusted during the normal speed phase*.
SEAV
99: maximum sensitivity – 0: Minimum sensitivity
The trigger time of the anti-crash device (Encoder) is adjusted during the braking phase*.
SEAR
99: maximum sensitivity – 0: minimum sensitivity
TLS
Activated only with SERL:ON Logic. The activation time of the service light is adjusted.
The force of the motor brake is adjusted.
ibra
0: disabled braking - 1:minimum braking - 99: maximum braking
Motor stop delay on limit switch. It is activated only with enabled braking (TSM).
The motor stop delay is adjusted after the triggering of the limit switch. Use a value calibrated
on the gate weight. Use these indicative values:
25
very heavy gates (longer delay)
blc
18
heavy gates
10
average gates
1
light gates (short delay)
0
deactivated (no delay)
MENU
The automatic closure is enabled or disabled
TCA
On: enabled automatic closure
Off: disabled automatic closure
The multi-flat function is enabled or disabled.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the transmitter
IbL
have no effect in the opening phase.
Off: disabled multi-flat function.
PP and PED controls are enabled or disable during the TCA phase.
IBCA
On: PP and PED control units are disabled.
Off: PP and PED control units are enabled.
The rapid closure is enabled or disabled
On: rapid closure is enabled. When the gate is open or moving, the photocell activation causes
SCL
the automatic closure of the gate after 3 s. It is activated only with TCA:ON
Off: rapid closure is disabled.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before the starting of
PRE
the motor.
Off: disabled forewarning flashing light.
During the TCA time, the blinker is enabled or disabled.
LTCA
On: Activated blinker.
Off: De-activated blinker.
The Operator function is enabled or disabled.
On: Operator function enabled.
htr
During operation, the OPEN/CLOSE push-buttons must be kept pressed.
Off: Automatic operation.
The Encoder is enabled or disabled. See section "Operating mode with enabled/disabled En-
coder"
ENC
On: Encoder enabled – The anti-crash sensor is activated.
Off: Encoder disabled – The anti-crash sensor is deactivated.
Enables or disables the programmable code transmitters.
IMPORTANT: The transmitters with programmable code can only be used in conjunction with the
Rolling Code HCS transmitters.
Cvar
On: Radio receiver enabled only for transmitters Rolling Code (ARC or HCS, the first transmitter
sets the operating mode).
Off: Receiver enabled for transmitters Rolling Code HCS and programmable (self-learning and
dip/switch).
26
An incorrect setting of these parameters may result in a danger.
Comply with regulations in force!
LOGICS (LOG)
FUNCTION
* WARNING:
1-99-(50%)
1-99-(50%)
0-99-(1%)
0-99-(1%)
1-240-(60s)
0-99-(80%)
0-25-(0)
DEFAULT
MEMO
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(ON)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis