Herunterladen Inhalt Inhalt Diese Seite drucken

Initial Start-Up; Connecting The Sensors; Turning On And Off - Bosch FSA 720 Betriebsanleitung

Fahrzeug-system-analyse
Vorschau ausblenden Andere Handbücher für FSA 720:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
4.

Initial start-up

4.1
Mounting
1. Remove the packaging of all delivered parts.
2. The FSA 720 must be permanently fastened to the
worktop (workbench) using the supplied retaining
panel, or mounted to a wall or a mobile base (trol-
ley). When assembling the weight of the sensors and
the center of gravity must also be taken into account.
If the FSA 720 is to be mounted onto a mobile base,
we recommend mounting it to a trolley (available as
supplementary equipment set 1 687 001 586).
If the FSA 720 is upturned then people may
be injured or material damage occur.
Always secure the FSA 720 against tipping
over, as in principle there is a risk that any-
one tripping up or pulling on the sensors
may pull the unit over.
4.2
Initial operation FSA 720
Prior to starting up for the first time make sure that the
lighting mains supply voltage matches the voltage specified
on the power pack (100 V – 240 V, 50/60 Hz).
i
The delivery specification includes the German mains
connecting cable. Other country-specific mains con-
necting cables are not part of the delivery specification.
4.3

Turning on and off

The voltage supply is established directly by way of the
power pack. The FSA 720 does not have an ON / OFF
switch.
1. Plug in power pack connecting cable on the FSA 720
(Fig. 2; Item 9).
2. Plug USB connecting cable into FSA 720
(Fig. 2; Item 7).
3. Secure USB connecting cable and power pack con-
necting cable on the retaining panel with two cable
ties for strain relief (Fig. 3, Item 1).
KV-
COM
15+
- 1
Fig. 3:
Strain relief on the retaining panel
1 Cabel tie
4. Plug USB connecting cable into PC.
5. Connect power pack to lighting mains.
Robert Bosch GmbH
X
D
KV+
CH1
CH2
15V DC
USB
459775/11Ko
1
Initial start-up | FSA 720 | 21
4.4

Connecting the sensors

Connect sensors to designated slots in measuring unit
(see Fig. 2). The measurement lead with voltage divider,
current probes 30 A and 1000 A and adapter cable
1 684 465 513 are only to be connected as required.
4.5
Software installation CompacSoft[plus]
i
Before starting installation check the system require-
ments. The FSA 720 can only be operated using a PC
with the CompacSoft[plus] software installed.
i
The software installation can be undertaken without
the FSA 720 hardware connected.
1. Close all open applications.
2. Place DVD "CompacSoft[plus]" into DVD disk drive
on PC.
3. Start "Windows Explorer".
4. START 'D:\RBSETUP.EXE' n (D = DVD drive letter).
 Set-up is started.
5. Heed and follow the instructions on the screen.
6. Restart the PC/Laptop to successfully conclude
installation.
 This completes CompacSoft[plus] installation.
 DSA is started.
en
|
1 689 979 894
2014-08-28

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis