Operation
!
Only transport the BEA 060 in an upright position. If
the BEA 060 is tilted during transportation, con-
densate may escape and damage the measurement
chamber. Select the installation location such that
the BEA 060 cannot fall down and is correctly posi-
tioned (carrying handle at top).
4.1

Power supply

The power supply is obtained from the lighting system.
The BEA 060 can be operated at between 100 V and
240 V, 50/60 Hz.
i
The BEA 060 can also be supplied with power by
way of the vehicle battery using the cigarette lighter
socket connecting cable (special accessory).
Refer to Fig. 1, Pos. 12 for connection.
!
Prior to start-up, make sure the lighting system volt-
age coincides with the set BEA 060 voltage. If the
BEA 060 is operated outdoors, it is advisable to use
a voltage source protected by a residual current-
operated circuit breaker. The unit is only to be oper-
ated in dry conditions.
!
To avoid the formation of condensation, allow the
BEA 060 to adjust to ambient temperature before
switching on the BEA 060.
i
The details of the power supply are given on
a sticker on the back of the BEA 060.
Robert Bosch GmbH
4.2

Switching unit on / off

4.2.1
Switch-on
1. Plug in the power cord at the BEA 060 and attach
the power cord at the holes (Fig. 1, Pos. 4) with
a cable tie to provide strain relief.
2. Connect the BEA 060 to the lighting system by way
of the power cord.
3. Press the On/Off button.
"
Alternate orange and green flashing of LED
(Fig. 1, Pos. 16).
4.2.2
Switch-off
To keep contamination of the BEA 060 to a minimum,
it is advisable to flush residual gas out of the BEA 060
prior to switch-off with the pump running. The sampling
probe must be in the open air for this purpose.
i
First exit from the exhaust gas test step and wait for
completion of pump run-on. Then switch off the BEA 060.
Press the On/Off button for three seconds.
"
The LED (Fig. 1, Pos. 16) goes out, the BEA 060 is
switched off.