Herunterladen Inhalt Inhalt Diese Seite drucken

Disposal; Troubleshooting; Technical Data; Spare Parts And Accessories - Emerson AVENTICS AV03 Montageanleitung

Ventilsystem montage und anschluss
Vorschau ausblenden Andere Handbücher für AVENTICS AV03:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

10 Disposal

Comply with national regulations regarding disposal.
u

11 Troubleshooting

If you cannot remedy a malfunction, please contact one of the addresses found
under www.emerson.com/contactus.

12 Technical Data

General data
Dimensions
Weight
Version (switching valves)
Version (AV-EP)
Operating temperature range
Storage temperature range
Ambient operating conditions
Relative humidity
Degree of contamination
Protection class according to EN 60529/
IEC529
Protection class to control cabinet
Mounting orientation
Use
Pneumatics
Medium
Control pressure
Operating pressure
Operating pressure (UL/CSA applica-
tion)
Max. particle size
Oil content of compressed air
The pressure dew point must be at least 15°C below the ambient and medium temperatures
and must not exceed 3°C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS.
u
Media temperature
Nominal flow
Electronics
Electronics power supply
Valve power supply
Valve inrush current
Current at maximum configuration
(multipole)
Multipole plug (25-pin)
Multipole plug (44-pin)
Rated current for both 24 V power supplies
(bus coupler)
Standards and directives
DIN EN 60204-1 "Safety of machinery – Electrical equipment of machines – Part 1: General
requirements"
EN 61000-6-2 Electromagnetic compatibility (EMC) –
Part 6-2: generic standards – interference immunity for industrial areas
EN 61000-6-4 Electromagnetic compatibility (EMC) –
Part 6-4: Generic standards – Emission standard for industrial environments
DIN EN ISO 4414 Pneumatic fluid power  - General rules and safety requirements for systems
and their components
1. Only use PELV electric circuits in accordance with EN 60204-1.
AVENTICS™ AV03/AV05 | R412018507-BAL-001-AJ | English
Depending on the configuration, see the online
catalog
Depending on the configuration, see the online
catalog
Spool valve, elastic seal
Externally piloted pressure regulator
ϑ
-10 °C to 60 °C
U
-25 °C to 80 °C
Max. height above sea level: 2000 m
95 %, non condensing
2
IP65 with assembled connections
IP54 with direct connection
IP65 with transition plate
Any
Only in closed rooms
Compressed air
3 bar/8 bar
-0.9 bar/10 bar
-0.9 bar/8 bar
40 µm
3
0 – 5 mg/m
ϑ
–10 °C to +60 °C
M
q
AV03: 300 l/min; AV05: 700 l/min
v
24 V DC ±25 %
24 V DC ±10 %
50 mA
24 x 50 mA
40 x 50 mA
Maximum 24 coils
Maximum 40 coils
4 A
2. Always establish the power supply using a safety isolation transformer in ac-
cordance with IEC 61558-1/IEC 61558-2-6 (EN 61558-1/EN 61558-2-6). Equiv-
alent solutions are permitted.
3. Make sure that the supply voltage for the power pack is always less than
300 V AC.
Further technical data can be found in the pages for individual components in the