2.6.4 - POWER OPTIMIZER (REQUIRES OPTIONAL ACCESSORIES)
This feature is provided with an optional metering accessories which are sold separately. In power
optimizer mode, the total current drawn from the main switch of the house by charging station
and other household appliances is measured with current sensor integrated to the main power
line. Current limit of the main power line of the system is set through the DIP switches inside the
charging station. According to the limit set by the user, charging station adjusts its output charging
current dynamically according to the measurement of main power line.
Last 3 DIP switch pins (4,5,6) corresponds to binary digits of the maximum current value as shown in
the table-12 below. When 4, 5, 6 pins are in OFF position, power optimizer functionality is disabled.
OFF
OFF
OFF
OFF
IG v7.3.0 2020
DIP Switch Positions
4
5
OFF
OFF
ON
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
© 2020 Vestel - All rights reserved
ON
ON
1
2
3
4
OFF
Figure-19
6
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Table-12
5
6
Current Limit Value

Power Optimizer

Disabled
16
20
25
32
40
63
80