7. START-UP AND OPERATION

Guidelines for System Connection
The connection should be executed in a way which does not induce
stresses.
It is recommended to install vent valves at the highest point of the
system.
The system should be executed so that, in the case of a failure, it is
possible to disassemble the device. For this purpose it is best to use
shut-off valves just by the device.
The system with the heating medium must be protected against an
increase of the heating medium pressure above the permissible value
(1.6 MPa).
While screwing exchanger to pipeline - connecting stubs has to be
hold by wrench.
Start Up
Before connecting the power supply check the correctness of
connection of the fan motor and the controllers. These connections
should be executed in accordance with their technical documentation.
Before connecting the power supply check whether the mains voltage is
in accordance with the voltage on the device data plate.
Before starting the device check the correctness of connection of the
heating medium conduits and the tightness of the system.
The electrical system supplying the fan motor should be additionally
protected with a circuit breaker against the effects of a possible short-
circuit in the system.
Starting the device without connecting the ground conductor is
forbidden.
Operation
The device is designed for operation inside buildings, at temperatures
o
C. In loа tОmpОrКturОs (ЛОloа ŃºC) tСОrО Тs К НКnРОr oП
above 0
freezing of the medium.
The manufacturer bears no responsibility for damage of the heat
exchanger resulting from freezing of the medium in the exchanger. If
operation of the devicО ТЬ ОбpОМЭОН КЭ ЭОmpОЫКЭЮЫОЬ loаОЫ ЭhКn 0º, ЭhОn
glycol solution should be used as the heating medium, or special
automatic systems should be used for protecting against freezing of
the medium in the exchanger.
It is forbidden to place any objects on the heater or to hang any objects
on the connecting stubs.
The device must be inspected periodically. In the case of incorrect
operation of the device it should be switched off immediately.
It is forbidden to use a damaged device. The manufacturer bears no
responsibility for damage resulting from the use of a damaged device.
If it is necessary to clean the exchanger, be careful not to damage the
aluminium lamellas.
It is recommended to use pressured air to clean the exchanger, air
stream need to be directed perpendicular to exchanger and moved along
lamellas. Max. pressure 8 bar.
For the time of performing inspection or cleaning the device, the
electrical power supply should be disconnected.
In case water is drained from the device for a longer period of time, the
exchanger tubes should be emptied with compressed air.
It is not allowed to make any modification in the unit. Any modification
causes in warranty loss.
| 10
www.flowair.com

7. URUCHOMIENIE I EKSPLOATACJA

АЬФКгяаФТ НoЭвМгąМО poНłąМгОnia do instalacji
PrгвłąМгО poаТnno Лвć авФonКnО а sposяЛ nТОpoаoНuУąМв nКprę О .
ГКlОМКnО УОst гКstosoаКnТО гКаorяа oНpoаТОtrгКУąМвМС а nКУав sгвm punФМТО
instalacji.
InstКlКМУК poаТnnК Лвć авФonКnК а tКФТ sposяЛ, КЛв а rКгТО КаКrТТ ТstnТКłК
mo lТаość prгОproаКНгОnТК НОmontК u КpКrКtu. А tвm МОlu nКУlОpТОУ УОst
гКstosoаКć гКаorв oНМТnКУąМО tu prгв urгąНгОnТu.
InstКlКМУК г МгвnnТФТОm РrгОаМгвm musТ Лвć гКЛОгpТОМгonК prгОН агrostОm
МТśnТОnТК МгвnnТФК РrгОаМгОРo ponКН НopusгМгКlną аКrtość (ń,6 MPК).
montК u
ТnstКlКМУТ
PodczКs
prгвłąМгОnТoаО авmТОnnТФК.
Uruchomienie
PrгОН poНłąМгОnТОm гКsТlКnТК nКlО в sprКаНгТć poprКаność poНłąМгОnТК sТlnТФК
wentylatora i stОroаnТФяа. PoНłąМгОnТК tО poаТnnв Лвć авФonКnО гРoНnТО z ich
НoФumОntКМУą tОМСnТМгną
PrгОН poНłąМгОnТОm гКsТlКnТК nКlО в sprКаНгТć Мгв nКpТęМТО а sТОМТ УОst гРoНnО
z nКpТęМТОm nК tКЛlТМгМО гnКmТonoаОУ urгąНгОnТК.
PrгОН uruМСomТОnТОm urгąНгОnТК nКlО в sprКаНгТć prКаТНłoаość poНłąМгОnТК
prгОаoНяа г czynnikiem grгОаМгвm orКг sгМгОlność ТnstКlКМУТ
InstКlКМУК ОlОФtrвМгnК, гКsТlКУąМК sТlnТФ аОntвlКtorК poаТnnК Лвć НoНКtФoаo
zabezpieczona bezpiecznikiem przed skutkami ewentualnego zwarcia w instalacji.
UruМСomТОnТО urгąНгОnТК
niedozwolone.
Eksploatacja
UrгąНгОnТО prгОгnКМгonО УОst Нo prКМв аОаnątrг ЛuНвnФu, а temperaturach
poав ОУ Ń
o
C. W nТsФТМС tОmpОrКturКМС (ponТ ОУ ŃºC) ТstnТОУО nТОЛОгpТОМгО stаo
гКmКrгnТęМТК МгвnnТФК.
PЫoНЮМОnЭ nТО ponoЬТ oНpoаТОНгТКlnośМТ гК ЮЬгФoНгОnТК авmТОnnТФК МТОpłК
ЛęНąМО ЬФЮЭФТОm гКmКЫгnТęМТК МгвnnТФК а авmТОnnТФЮ. JОżОlТ pЫгОаТНЮУО ЬТę
pЫКМę ЮЫгąНгОnТК а ЭОmpОЫКЭЮЫКМh nТżЬгвМh nТż 0º nКlОżв гКЬЭoЬoаКć ЫoгЭаяЫ
РlТФolЮ УКФo МгвnnТФ РЫгОаМгв lЮЛ ЭОż гКЬЭoЬoаКć ЬpОМУКlnО ЮФłКНв КЮЭomКЭвФТ
zabezpieczająМО pЫгОН гКmКЫгnТęМТОm МгвnnТФК а авmТОnnТФЮ.
NТО
аolno
umТОsгМгКć
prгвłąМгОnТoавМС КНnвМС prгОНmТotяа
ApКrКt musТ poНlОРКć oФrОsoавm prгОРląНom. Prгв nТОprКаТНłoаОУ prКМв
urгąНгОnТК nКlО в Рo nТОгаłoМгnТО авłąМгвć.
NТО
аolno
ЮżваКć
ЮЬгФoНгonОРo
oНpoаТОНгТКlnośМТ гК ЬгФoНв авnТФłО poНМгКЬ ЮżвЭФoаКnТК ЮЬгФoНгonОРo
ЮЫгąНгОnТК.
JО ОlТ авstąpТ ФonТОМгność МгвsгМгОnТК авmТОnnТФК nКlО в uаК Кć КЛв nТО
usгФoНгТć КlumТnТoавМС lКmОl. Nie zalОМК sТę u ваКnТК ostrвМС prгОНmТotяа Нo
МгвsгМгОnТК, гО агРlęНu nК mo lТаość usгФoНгОnТК lКmОl.
ГКlОМК sТę МгвsгМгОnТО sprę onвm poаТОtrгОm. CгвsгМгОnТО nКlО в авФonваКć
ruМСКmТ агНłu lКmОl, ФТОruУąМ Нвsгę nКНmuМСoаą prostopКНlО Нo авmТОnnТФК.
MКб. МТśnТenie 8 bar.
NК МгКs prгОproаКНгКnТК prгОРląНu ЛąН МгвsгМгОnТК КpКrКtu ФonТОМгnТО nКlО в
oНłąМгвć гКsТlКnТО ОlОФtrвМгnО.
А prгвpКНФu РНв аoНК г urгąНгОnТК гostКУО spusгМгonК nК Нłu sгв oФrОs МгКsu,
nКlО в НoНКtФoаo prгОНmuМСКć rurФТ авmТОnnТФК sprę onвm powietrzem.
NТОНoгаolonО są УКФТОФolаТОФ moНвПТФКМУО urгąНгОnТК. АsгОlФК ТnРОrОnМУК а
ФonstruФМУę urгąНгОnТК poаoНuУО utrКtę РаКrКnМУТ.
nКlО в
ЛОгагРlęНnТО
unТОruМСomТć
ЛОг poНłąМгОnТК prгОаoНu uгТОmТКУąМОРo
nКРrгОаnТМв,
КnТ
гКаТОsгКć
ЮЫгąНгОnТК.
PЫoНЮМОnЭ
ФrяćМО
УОst
ФrяćМКМС
nТО
ЛТОЫгО