Herunterladen Inhalt Inhalt Diese Seite drucken

Diagnostic And Troubleshooting; Indicator Light Status; Diagnostic - simu SIMUDRIVE SD100hz Installationsanleitung

Vorschau ausblenden Andere Handbücher für SIMUDRIVE SD100hz:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 42
SIMUDRIVE SD100Hz

11 DIAGNOSTIC AND TROUBLESHOOTING

11.1 Indicator light status

Off
Permanently lit

11.2 Diagnostic

POWER indicator
Electronic in motor setting mode
→ If necessary, check the direction of rotation of the motor and adjust the motor end limits.
Product adjusted
Motor thermal cut-out
→ Switch the power supply off, wait about 5 min. then switch the power supply back on.
Photoelectric cells indicator light
Normal operation
• Detection in progress
→ Once detection is complete, the indicator light goes out.
• Permanent fault
→ Check the alignment and wiring of the cells.
NOTICE! After 3 mins, the wired control input (terminals 20 and 21) allows the door
to be controlled in dead-man mode.
Auto-test in progress
→ Once the auto-test is complete, the indicator light goes out.
Safety edge indicator light
• Normal operation
• If the safety edge is not activated when the door encounters an obstacle when closing,
the direction of rotation of the motor must be checked.
• Detection in progress
→ Once detection is complete, the indicator light goes out.
• Permanent fault
→ Check the safety edge wiring.
NOTICE! After 3 mins, the wired control input (terminals 20 and 21) allows the door
to be controlled in dead-man mode.
Auto-test in progress
→ Once the auto-test is complete, the indicator light goes out.
Fall protection indicator light
Normal operation
Slow flashing
Rapid flashing
Very rapid flashing
EN