3

INSTALLATION

3.1

Mounting the receiver

> Illustration 4
CAUTION
Ensure the mains power supply is at the correct distance.
1] Secure the bracket to the wall.
2] Secure the housing to the bracket.
3.2

Wiring the motor

> Illustration 5
DANGER
Risk of electrocution
The receiver must not be connected to the mains power supply during connection to the motor.
The motor cable must be placed in the receiver's 230 V insulation area.
1] Connect the motor to the receiver in accordance with the wiring shown below:
Receiver terminal
4
5
6
7
NOTICE
The motor's direction of rotation shall then be checked and reversed if necessary.
3.3

Anti-fallback wiring

> Illustration 6
DANGER
The anti-fallback device must be wired.
3.4

Power supply wiring

> Illustration 7
1] Connect the neutral (N) to terminal 1 of the receiver.
2] Connect the live (L) to terminal 2 of the receiver.
3] Connect the earth wire to terminal 3 of the receiver.
4] Lock the power supply cable with the cable clamp provided.
WARNING
The earth wire must always be longer than the live and neutral to ensure that it is the last to be dis-
connected if the connector is pulled out.
The cable clamp supplied must be used.
For all low-voltage cables, ensure that they can withstand traction of 100 N. Check that the conduct-
ors do not move when this traction is applied.
30
Motor wire
Yellow/green
Black
Blue
Brown
SIMUDRIVE SD100Hz