CAUTION
The order of these operations must be complied with.
1] Remove the bridge between terminals 19 and 20.
2] Connect the cells.
• A - without auto-test
• B - with auto-test: allows an automatic operating test to be conducted on the photoelectric cells
every time the doors moves.
3] Program parameter P3.
• Active without auto-test: "P3" = 1
• Active with auto-test by means of power switching: "P3" = 2
Meaning of the different parameters [} p.36]
5.2.2
Reflex photocell
> Illustration 15
WARNING
It is compulsory to install photoelectric cells WITH AUTO-TEST P3 = 3 if:
• remote control of the mechanism is used when the door is not visible,
• automatic closing is activated ("P0" = 2 or 3).
CAUTION
The order of these operations must be complied with.
1] Remove the bridge between terminals 19 and 20.
2] Connect the cell.
3] Program parameter "P3" = 3.
Meaning of the different parameters [} p.36]
5.2.3
230 V orange light
> Illustration 16
WARNING
A cable clamp must be used (not supplied).
The output must be protected by a 5 A time-delay fuse (not supplied).
Program parameter "P1" = 1.
Meaning of the different parameters [} p.36]
5.2.4
230 V area lighting
> Illustration 17
WARNING
The earth wire must always be longer than the live and neutral wires in case of detachment.
A cable clamp must be used (not supplied).
The output must be protected by a 5 A time-delay fuse (not supplied).
1] For class I lighting, connect the earth wire to the earth terminal.
2] Program parameter "P1" = 2.
Meaning of the different parameters [} p.36]
Lighting output power:
• either 5 fluocompact or LED lights
• or 2 power supplies for low-voltage LEDs
• or 1 halogen light, max. 500 W