Herunterladen Inhalt Inhalt Diese Seite drucken

Motor End Stop Setting; Memorising Remote Controls; Checking The Conformity Of The Installation; Operating Test - simu SIMUDRIVE SD100hz Installationsanleitung

Vorschau ausblenden Andere Handbücher für SIMUDRIVE SD100hz:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 42
EN
3.7

Motor end stop setting

Consult the motor manual.
3.8

Memorising remote controls

> Illustration 11
NOTICE
If this procedure is carried out using a button which has already been memorised, the button will be
cleared.
1] Press the "PROG" button for 2 s.
ð The "PROG" indicator light is permanently lit.
2] Press the button selected to control the function (complete opening, Aux 230 V output control).
ð The "PROG" indicator light flashes for 5 s.
è The remote control has been memorised.
3.9

Checking the conformity of the installation

WARNING
Once installation is complete, it is essential to check that the obstacle detection system complies with
Annex A of the standard EN 12453.
4

OPERATING TEST

4.1

Complete opening operation

> Illustration 12
4.2

Photoelectric cells operation

Cells obscured when opening = the state of the cells is disregarded, and the door continues to move.
Cells obscured when closing = stop + complete reopening.
4.3

Safety edge operation

Activation of the safety edge when opening = disregarded, the door continues moving.
Activation of the safety edge when closing = stop + partial reopening.
4.4

Specific modes

See the user booklet.
4.5

User training

Train all users in how to use this motorised door safely (standard use and locking principle) and in the man-
datory periodic checks.
32
SIMUDRIVE SD100Hz

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für simu SIMUDRIVE SD100hz

Inhaltsverzeichnis