english
Danger!
Mains voltage!
In the case of contact with uninsula-
ted parts carrying mains voltage the-
re is a risk of electric shock including
injury or death!
Measures:
Observe all the valid rules and regu-
lations for electrical installation (VDE
0100) !
The removed control unit does no lon-
ger have IP protection and must be pro-
tected from damp!
CAUTION! Maintenance work must only
be carried out when the device is in a
de-energized state! Any work involving
electrical parts must only be performed
by suitably qualified and authorized per-
sonnel.
Note before wiring:
• Check type plate for permissible
mains voltage and ensure confor-
mity!
• The installation must be carried out
according to the valid regulations.
• Assign terminals as indicated!
• Electrical power must be discon-
nected prior to installation!
• Remove screw (1) and lift off top cover
(2)
• Unscrew cable fitting (3) , remove blan-
king plug and insert cable (4) for power
supply (1).
• Connect cable (4) to terminals (5).
Terminal assignment: VAC
KL1.1
L- or N-mains connection
KL1.2
N- or L-mains connection
KL1.3
PE-mains connection
L = phase conductor (black)
N = neutral conductor (blue)
PE = protective earth conductor
(green/yellow)
Terminal assignment: VDC
KL1.1
+24 VDC
KL1.2
0V
KL1.3
PE-mains connection
Note: There is no metallic isolation
between terminals KL1.1 - 1.3 VDC
units and housings and the condensate
connections.
The 24 VDC voltage supplied must meet
the requirements for extra-low safety
voltages (for instance, EN 61556-2-6).
BEKOMAT 32 stand alone
français
Danger !
Tension de réseau !
Risques de blessures ou de mort par
électrocution en cas de contact avec
des pièces non isolées conductrices
de la tension de réseau !
Mesures de précaution :
Respecter
toutes
les
tions en vigueur (VDE 0100) lors de
l´installation électrique.
L´unité de commande démontée ne bé-
néficie alors plus du degré de protection
IP et doit être absolument préservée de
toute humidité !
ATTENTION ! les travaux de mainte-
nance ne peuvent être effectués que
lorsque l´appareil n´est pas sous tension
! Seul un personnel qualifié et autorisé
est habilité à effectuer les interventions
électriques.
A noter avant l'installation
électrique:
• Respecter impérativement la tension
secteur admissible mentionnée sur
la plaque signalétique !
• Réaliser les travaux d'installation
conformément à VDE 0100.
• Respecter l'affectation des bornes!
• Ne pas travailler sous tension !
• Dévisser la vis (1) et retirer le capot
avant (2).
• Desserrer le presse-étoupe (3), retirer
l'obturateur et insérer le câble (4) pour
l'alimentation électrique (1).
• Raccorder le câble (4) aux bornes (5).
Affectation des bornes: VAC
KL1.1
L ou N = phase ou neutre de
l'alimentation
KL1.2
N ou L = phase ou neutre de
l'alimentation
KL1.3
PE-terre de l'alimentation
L = phase (noir)
N = neutre (bleu)
PE = terre (vert/jaune)
Affectation des bornes: VDC
KL1.1
+24 VDC
KL1.2
0V
KL1.3
PE-terre de l'alimentation
Attention: Entre les bornes KL1.1 - 1.3
des appareils VDC et le corps ou l e s
raccords des conduites de condensat,
il n'y a pas d'isolation galvanique.
La tension disponible de 24 VDC doit
remplir les conditions de sécurité de
basse tension (par ex: EN 615556-2-6)
български
Опасност !
Мрежово напрежение !
Чрез контакт с проводящи мрежово-
то напрежение неизолирани части
съществува опасност от електриче-
ски удар, който води до нараняване
и смърт!
Мерки:
Да се спазват всички валидни раз-
поредби при електрическите ин-
prescrip-
сталации (VDE 0 100) !
Снетият управляващ блок не раз-
полага повече с клас на защита IP и
трябва да се предпазва от влага !
ВНИМАНИЕ ! Работите по поддръж-
ката трябва да се извършват само ко-
гато уредът не е включен в електри-
ческата мрежа! Всички електрически
работи трябва да се извършват само
от квалифициран персонал.
Преди електрическата инста-
лация трябва да се съблюда-
ва следното:
• Да се контролира допустимото
мрежово напрежение върху ти-
повата табелка и то да се спазва
непременно!
• Инсталационните работи да се
извършват съгласно VDE 0100.
• Да се съблюдава разположението
на клемите!
• Да не се инсталира при включено
напрежение!
• Развинтва се болтът (1) и се снема
горната част на капака (2).
• Развинтва се болтовото съединение
на кабела (3) (ако има такова), отстра-
нява се тапата и се прокарва кабелът
(4) за източника на захранване (1).
• Кабелът (4) се свързва към клемите (5).
Разпределение на клемите VAC
KL1:1
PE включване в мрежата
KL1:2
L или N включване в мрежа-
та
KL1:3
N или L включване
Разпределение на клемите: VDC
KL1:1
PE-връзка
KL1.2
0V
KL1.3
+24 V
Внимание: Между клемите KL1.1
KL1.3 на VDC уредите и корпуса
респ. кондензатните връзки не съ-
ществува галванично разделяне.
Предоставеното напрежение 24 VDC
трябва да изпълнява изискванията за
безопасни малки напрежения (напр.
EN 61556-2-6).
15