Notice!
Risk of damage due to excessively high motor speed
An excessively high motor speed can damage the agitator.
→ Never allow the agitator to run without a load, and choose a motor
speed that is just high enough to ensure proper agitation.
The agitator motor speed can be infinitely adjusted using the air microme-
ter [11-2] / [12-2] / [15-1] / [16-1].
■ Turning it counter-clockwise increases the agitator speed.
■ Turning it clockwise decreases the agitator speed.
Motor driven agitator
Notice!
Risk of damage from overheating
Excessively high temperatures will damage the electric motor.
→ Make sure that the ventilation slots of the motor are not obstructed
while the electric agitator is in use.
■ Use the external control unit to switch the motor-driven agitator on and
off.
10.2. Setting up the paint and atomizing air supply
Danger!
Risk of injury caused by disconnected paint material and
compressed air pipes
Escaping paint material and improperly connected compressed air pipes
can result in injuries.
→ Make sure the paint material and compressed air pipes are securely
attached.
■ Open ball valve for compressed air supply [3-9] / [4-9] / [5-2] /[6-1].
Single pressure reducer version
■ Open ball valve for atomizing air [3-7] / [5-4].
Version with a second spray gun connection
■ Open ball valve for atomizing air [7-4] / [8-1].
■ Open ball valve for paint supply [2-7] / [3-1] / [4-1] / [5-8] / [6-7] / [7-1] / [8-4
].