• Refi t the ti ghtening ring, reconnect the cell cable and refi t the protecti ve cover. Open the isolati on valves and restart
the fi ltering and chlorinator.
• If you do not use a commercially available cleaning soluti on, you can manufacture it yourself by carefully
mixing 1 volume of hydrochloric acid with 9 volumes of water (Warning: always pour the acid into the water
and not the opposite and wear suitable protecti ve equipment!).
• Make sure that the setti ng of the polarity inversion cycles is adapted to the pool water hardness. See "3.2.6.b
Polarity inversion" to change them.
4.3 Winterizing
The chlorinator has a protecti ve system to limit chlorine producti on under poor operati ng conditi ons such as cold
water (winter) or a lack of salt.
• Acti ve winterizing = fi ltering operati onal in winter: below 10 °C it is preferable to switch off the chlorinator. Above this
temperature you can leave it running.
• Passive winterizing = lower water level and drained piping: leave the electrode dry in its cell with its isolati on valves
open.
5. Troubleshooti ng
Ei²
Ei²Expert
GenSalt OE
INVERSION
«FLASH»
/
HIGH SALT
"Salt" indicator
CHECK SALT
on
"Flow" indicator
NO FLOW
on
PUMP
/
CONTROLLER
OUTPUT
FAULT
/
13
Possible causes
The self-cleaning cycle is automati c;
this message is not an error code
but an informati on message.
• Salt overload (> 10 g/L).
• Lack of salt (< 3g/L) due to water
loss or diluti on (fi lter backwash,
water renewal, rain, leaks, etc.).
• Pool water temperature too low
(< 18 °C, variable).
• Cell scaled up or worn.
• Stop or failure of the fi ltering
pump.
• Presence of air or gas in the cell
(incorrect fi lling with water).
• By-pass valves closed.
• Flow controller and/or cell
disconnected or defecti ve.
• This message is displayed
alternately with "NO FLOW" if
the situati on conti nues.
• Short-circuit in the cell or cable
disconnected/badly connected.
• Worn electrode.
• Important manque de sel, ou pas
de sel.
• Sel non encore suffi samment
dilué.
Soluti ons
• Wait for about 10 minutes and chlorine
producti on will resume automati cally at
the previously set level.
• Drain the pool parti ally to reduce the salt
concentrati on.
• Add salt to the pool to keep the level at
4 g/l. If you do not know the salt level or
how to test it, consult your reseller.
• Basic producti on limitati on signal when
the water is too cold. Reduce chlorine
producti on or add salt to compensate.
• Clean or replace the cell.
• Check the pump and its programming
clock, the fi lter, the skimmer(s), and the by-
pass valves. Clean them if necessary.
• Check the cable connecti ons (cell and fl ow
controller).
• Check that the fl ow controller is working
correctly (replace it if necessary).
• Perform the same checks as above.
• Check the cell connecti ons.
• Replace the cell.
• Have the control box (electronic board
and transformer) checked by a qualifi ed
technician if necessary.
• Ajouter du sel dans la piscine pour
maintenir un niveau à 4 g/L.