Herunterladen Inhalt Inhalt Diese Seite drucken

Automatic Shut Off; Receiver Shut Off / Turn Down Attributes - Maxitrol GV60 Installations- Und Bedienungsanleitung

Elektronisches zünd- und steuersystem mit fernbedienung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OPERATING INSTRUCTIONS
1 Hour Turn Down for Special Receiver
(optional; requires special receiver and handset software)
▪ The valve will turn to pilot flame if there is no change in
flame height over a 1 hour period.

AUTOMATIC SHUT OFF

Low Battery Receiver
▪ With low battery power in the receiver the system shuts off
the fire completely. This will not happen if the power supply
is interrupted.
On-Demand Pilot (5 Day Shut-Off)
▪ This green feature eliminates gas energy consumption dur-
ing extended appliance inactivity. When the appliance is
inactive for an extended period of time the system automat-
ically extinguishes the pilot. This feature helps the consum-
er realize cost benefits by automatically eliminating energy
consumption during non-heating months and limited use.
▪ The programmed length of inactivity to activate the system
is specified by the appliance manufacturer and cannot be
altered in the field.
2
Thermocouple Shut Off
nd
(optional)
▪ The system shuts off the fire if the main burner does not
completely ignite approximately 20 seconds after ignition
or after pushing
(large flame) button.
NOTE:
Before the next ignition there is a 2 minute waiting
period. If the thermocouple is then still too hot, you
will hear a long beep.

RECEIVER SHUT OFF / TURN DOWN ATTRIBUTES

EU-Versions (CE)
G6R-R4AM (Standard)
▪ 176 °F (80 °C) turn down to pilot is NOT supported
▪ 5-day shut off. (If no motor movement for 5 days.)
G6R-R4AU (Universal)
▪ Turn down to pilot at 176 °F (80 °C) (with and without con-
nected module)
▪ Turn down to pilot at 140 °F (60 °C) when batteries installed
in the receiver battery compartment
▪ 5-day shut off. (If no motor movement for 5 days.)
U.S. Versions (CSA)
G6R-R3AM (Standard)
▪ 176 °F (80 °C) turn down to pilot is NOT supported
▪ 7-day shut off. (If no motor movement for 7 days.)
G6R-R3AU (Universal)
▪ Turn down to pilot at 176 °F (80 °C) (with and without con-
nected module)
▪ 7-day shut off. (If no motor movement for 7 days.)
▪ 8 hour turn down to pilot. (If no motor movement for 8 hours.)
▪ Turn down to pilot at 140 °F (60 °C) when batteries installed
in the receiver battery compartment.
20 / 20
FOR OEM USE ONLY

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading