OPERATING INSTRUCTIONS
TO OPEN AND CLOSE SOLENOID VALVE/BURNER
NOTE:
The latching solenoid valve cannot operate manu-
ally. If the battery runs down it will remain in the last
operating position. During normal operation the sole-
noid valve will be reset to the ON position when the
GV60 is switched OFF remotely.
▪ Upon ignition Main Burner and Decorative
Burner are ON.
▪ Simultaneously press SET and
flame) buttons to switch the Burner OFF.
Printed instructions are on the battery cover
(see figure 26).
▪ Simultaneously press SET and
flame) buttons to switch Burner ON. (The
AUX symbol on the display indicates the so-
Burner OFF
lenoid valve is OPEN.)
NOTE:
The operation of the AUX is blocked
in timer OFF mode, when the setting
of the
ture is "
Burner ON
Figure 26: Instructions for Latching Solenoid Valve (on battery cover)
LIGHT/DIMMER OPERATION
▪ Briefly press SET button to scroll to
bulb) mode. Light bulb icon flashes.
▪ Press and hold
turn ON the light or increase brightness.
▪ Press and hold
crease brightness.
▪ In the Light/Dimmer mode, the OFF button
shuts OFF the light.
▪ If you want the light ON but no flame, press
and hold the
to pilot flame.
NOTE:
The light bulb icon is displayed during light/dim-
mer setting only. 8 seconds after the light/dimmer
has been set, the handset will automatically go into
temperature control mode (CSA version) or manual
mode (CE version).
(small
(large
Nighttime Setback Tempera-
".
(light
(large flame) button to
(small flame) button to de-
(small flame) button and turn
CIRCULATING FAN OPERATION
The circulating fan has 4 speed levels from low (1 bar) to
high (4 bars).
▪ Briefly press SET button to scroll to
(fan) mode. Fan and Level icons flash.
▪ Press
and increase fan speed.
▪ Press
fan speed.
▪ To turn OFF fan, press
ton until all 4 speed level bars disappear.
NOTE:
8 seconds after the fan has been set, the handset
will automatically go into temperature control mode
(CSA version) or manual mode (CE version). The
fan starts 4 minutes after the gas opens (from OFF
or from pilot) at maximum speed and goes to the
displayed level after 10 seconds. The fan stops 10
minutes after the gas is OFF or at pilot.

MODES OF OPERATION

▪ Briefly pressing the SET button changes the
mode of operation in the following order:
 M AN→  TEMP→ →
TIMER→back to the beginning
NOTE:
Manual mode can also be reached by pressing either
the
(large flame) or the
▪ MAN – Manual Mode
Manual flame height adjustment.
(Appliance must be in standby mode; pilot
ignited)
The room temperature is measured and
compared to the set temperature. The
flame height is then automatically adjusted
to achieve the Daytime Set Temperature.
Turns light/dimmer ON and OFF and ad-
justs brightness.
16 / 20
FOR OEM USE ONLY
(large flame) button to switch ON
(small flame) button to decrease
(small flame) but-
(small flame) button.
– Daytime Temperature Mode
– Light/Dimmer Setting Mode
→  TEMP →