Automatic Turn Down - Maxitrol GV60 Installations- Und Bedienungsanleitung

Elektronisches zünd- und steuersystem mit fernbedienung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OPERATING INSTRUCTIONS
2. Turn main valve knob to the OFF, full clockwise
position.
3. Turn MANUAL knob to the MAN, full clockwise
sition.
4. Place ON/OFF switch (if equipped) in O (OFF position).
5. Wait five (5) minutes to clear out any gas. Verify that no
gas is in the area around the appliance, including near
the floor. If you detect gas STOP! Follow "WHAT TO
DO IF YOU SMELL GAS" in the safety information on
page 2. If no gas is present, proceed to step 6.
6. Place ON/OFF switch (if equipped) in I (ON position).
7. With the MANUAL knob in MAN position a manual pilot
valve operator and piezo ignitor (optional) are accessible.
8. Fully push down manual pilot valve operator and hold in,
to start pilot gas flow (see figure 27).
IGNITION WITH MATCH:
Immediately light the pilot with a match, while continuing
to hold in the manual pilot valve operator for about one
(1) minute after the pilot is lit. Release manual pilot valve
operator. If pilot does not stay lit, wait five (5) minutes and
repeat.
IGNITION WITH PIEZO IGNITOR:
Change the ignition cable from the receiver to the valve
(see figure 27). Push in the piezo ignitor to ignite. If pilot
does not stay lit, wait five (5) minutes and repeat.
If the pilot does not stay lit after several tries, turn the main
valve knob to OFF and proceed to step 12.
9. If applicable, replace pilot access panel before proceed-
ing.
10. Turn MANUAL knob to the ON, full counter-clockwise
position.
11. Turn main valve knob to the full ON, full counter-clock-
wise
position.
12. If the appliance will not operate, follow the instructions
"TURN OFF GAS TO APPLIANCE".
Piezo ignitor
(optional)
ON/OFF switch
(optional) in
ON Position
8 Wire
receiver jack
Micro switch
Figure 27: Combination control, cover
TO TURN OFF GAS TO APPLIANCE
1. Place ON/OFF switch (if equipped) in O (OFF position).
po-
2. If gas control is accessible turn main valve knob to the
OFF full clockwise

AUTOMATIC TURN DOWN

8 Hour No Motor Movement
(CSA Version)
The valve will turn to pilot flame if there is no motor move-
ment for an 8-hour period. To deactivate or activate the
8-hour no motor movement turn down, the handset must be
synchronized with the Receiver and the Receiver must be
powered ON.
NOTE: 8-hour No Motor Movement turn down is the default
Deactivate 8-hour no motor movement turn down
NOTE: Deactivation remains in effect after changing the bat-
Activate 8-hour no motor movement turn down
Connection
piezo ignitor
tab 2.8 x 0.8 mm
MANUAL knob
in MAN position
Manual pilot
valve operator
NOTE: Activation remains in effect after changing the batteries
Receiver Overheating (G6R-R3(4)AU(T) only)
▪ Valve turns to pilot flame if the temperature in the receiver
Main valve knob
is higher than 176 °F (80 °C) or 140 °F (60 °C) when batter-
in OFF position
ies installed in the receiver battery compartment. The main
burner comes back on only when the temperature is below
176 °F (80 °C).
19 / 20
FOR OEM USE ONLY
position.
setting. Deactivation is only possible using the G6R
display/thermostat handset.
1. Press and hold the Down button.
2. Install the battery in the handset while con-
tinuing to press and hold the Down button.
3. Continue to press and hold the Down but-
ton for 8 sec.
4. During the 8 sec., 8h is displayed and the
last set status (ON/OFF) will flash.
5. When deactivation is completed, 8h and
OFF will appear on the display for 4 sec.
6. The Receiver confirms deactivation with 3
short beeps.
teries in the Receiver and Handset.
1. Press and hold the Up button.
2. Install the battery in the handset while con-
tinuing to press and hold the Up button.
3. Continue to press and hold the Up button
for 8 sec.
4. During the 8 sec., 8h is displayed and the
last set status (ON/OFF) will flash.
5. When activation is completed, 8h and ON
will appear on the display for 4 sec.
6. The Receiver confirms activation with 2
short beeps.
in the Receiver and Handset.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading