INSTALLATION
Place the connecting strip (33) in its original position in the lower part of the cabinet.
Cabinet door installation
Align the door with the cabinet, connect the grounding lead to the door and install the door to
the cabinet using 2 screws.
A compressor with air dryer must not be inserted to the cabinet to the stop as
there is a risk of permanent damage to the dryer.
Opening the upper cover (DK50 2x2V/110 - Fig. 3)
Open the lock by turning with a screwdriver as show in the pictogram ad pick up using the
handle
The gas springs will keep he cover open
Be careful not to pinch your fingers when closing the cover on the cabinet.
Always lock with the quick release after closing the cover on the cabinet!
Removal of the front panel on the cabinet
Remove the door held on by the 4 (four) M5 screws and disconnect the earthing conductor
Compressor placement
Insert the compressor into the cabinet so the compressed air outlet is pointing towards the
operator
The dryer fan must be inserted into the ventilation tunnel in the cabinet on compressor models
with a dryer
Cabinet door installation
Align the door with the cabinet, connect the grounding lead to the door and install the door to
the cabinet using 4 screws.
10.3. Adding sound-insulating material into the cabinet (DK50 2V/50)
A component from the sound-insulating material is to be installed in the opening of the cabinet of the
compressor without a dryer.
This component is provided in the basic equipment delivered with the product.
03/2020
29