Mounting and Operating Instructions proX Keyswitch BUS-2
12.5.2
Permanent
with manual activation
If manually activated, the door can be opened any number of times and remain open for any length of
time (deactivated without time limitation). Activation is performed using an ID pass card or key.
Operating
9 Sequence 9
or
or
12.5.3

Permanent release with automatic activation

When deactivated, a further operation for longer than 3 seconds can activate permanent release
(regardless of programming).
The door then has to be opened during the door release time.
The door can then remain open for any length of time without any reminder signal.
Activation is performed automatically the first time the door is closed.
Operating
9 Sequence 9
or
or
13
Required software: MB24/48/100 from V18.xx, MB-Secure fromV04.xx (see 2.3)
Duration
Operating state
Doorguard active
> 3 seconds
Permanent release*
Permanent release*
permanent door
release permitted,
irrespective of
parameterization
Stopp permanent
release
Doorguard active
Duration
Operating state
Doorguard active
> 200 ms
Doorguard inactive
> 3 seconds
Permanent release
Operation during
Open the door within
door lock release
the door opening time
Permanent release
permanent door
release permitted,
irrespective of
parameterization
Doorguard active
when the door is
Red LED
"Activation"
Off
Door open
–>LED lights up
Door closed
–>LED off
Off
13
Red LED
"Activation"
Off
Off
Lights up (static)
when door is
opened
Off
closed
53
Green LED
"Operating state"
Lights up (static)
Lights up (static)
Green LED
"Operating state"
Lights up (static)
Lights up (static)

Werbung

Kapitel

Inhaltsverzeichnis
loading