Mounting and Operating Instructions proX Keyswitch BUS-2
11.
Operation Instructions Amok alarm signalling device
11.1
Overview
The proX Keyswitch can only be operated by authorized persons as follows:
- With key operation
or
- With ID data carrier (recommended)
Operation with the integrated reader is possible irrespective of whether a half cylinder is being used or not.
11.2
Operation with key
Turn key clockwise to the limit.
On releasing the key, the key returns into the normal position.
11.3
Operation with ID data carriers
The device has an integrated reader for IK2/proX1 and IK3/proX2 ID data carriers.
The number of possible data carriers depends on the corresponding control panel:
- 561-MB24:
32 data carriers
- 561-MB48:
128 data carriers
- 561-MB100: 1024 data carriers
- MB-Secure: up to 10000 data carriers (depending on license)
The antenna of the receiver module for the ID data carrier is located above the mounting
position for the half cylinder.
The position is marked on the housing with the symbol
The optimum reading distance is 0 – 3 cm.
Hold ID cards parallel to the housing and keyrings at a right angle.
Note: If the device is programmed to "power-saving mode", then the scanning procedure
could take a bit longer (up to approx. 0.5 sec.).
11.4
LED indication
LED green on:
Ready for operation
LED green flashes: "Alarm triggered" acknowledgment signal
The duration of flashing depends on the programmed door lock release.
11.5
Delete alarm message
Only authorized persons can delete the alarm message via the control panel.
.
49