Mounting and Operating Instructions proX Keyswitch BUS-2
3.6

Programming

The DIP switches are only queried during initialization (when the operating voltage is applied). Therefore,
the setting of this switch is only effective when energized!
3.6.1

BUS-2 user address

The DIP switches 1 to 6 on the connection PCB is used for coding the BUS-2 user
address.
Address range: 0 to 63
The illustration on the right shows various examples.
The individual codes can be found in the programming protocol of the intruder alarm
control panel. The control panel automatically identifies the user type in the function
"Determine BUS-2 users" (561-MB24/48/100 Function 502).
3.6.2

Programming data carriers

The ID data carriers can be defined, authorized and managed via the connected intruder alarm control panel using
a corresponding validity list. The authorized data carrier ID is identical (function) with key switch operation of the key
operating unit.
The authorized data carrier ID is identical (function) with key switch operation of the key operating unit.
Data carrier transmission: Every ID data carrier at the proX Keyswitch is also transmitted to the control panel
irrespective of the function at the proX Keyswitch.
3.6.3

System parameters

proX Keyswitch BUS-2 system parameters are programmed via the programming software of the intruder alarm
control panel.
-
Set up the proX Keyswitch BUS-2 as a switching device.
-
Assign data carriers to the switching device/time zone.
-
The virtual input "Doorguard inactive" must be assigned to a hold-up alarm detector group.
-
Assign channels on the transmission device DS xxxx.
-
Reading mode (standard or energy-saving mode, see chapter 5.2)
-
Programming the door lock release.
In this application, the door lock release (deactivation) is the time required for optical acknowledgement when
an alarm is triggered (green LED flashes).
For more information, see user manual "WINFEM Advanced" or "IQ PanelControl".