48
9.
Final assembly
Close housing
- Use a cable binder to attach the connecting cables to the pull relief.
If required, attach the cables to the cable clip for cable routing.
- Insert the housing cover of the operating unit in the housing base (at
top) and put it over the locking cylinder on the housing base.
- Tighten the housing screws at bottom of the housing.
Seal housing
Seal the housing after correctly mounting, connecting, programming and testing the system. Ensure that both
housings are correctly closed and screwed tight. Press the enclosed plastic seals into the screw openings at the top
and bottom of the housings to seal. Clean the seal (remove grease) and cover with the label (VdS imprint). After
attaching the plastic seal, the housing can no longer be opened without destroying the seal.
10.
Technical data
Operating voltage U_b
Operating voltage range
Current consumption
Detector group voltage
Detector group end-of-line resistor
Monitoring range
Output for acoustical alarm signalling
Output for optical alarm signalling
Transponder reader
Frequency range, Transmission power
Half cylinder as per DIN 18252
Operating temperature range
Storage temperature range
Environmental class as per VdS
Protection class as per EN 60529
Dimensions (W x H x D)
Colour
Hereby, the Novar GmbH declares that the radio equipment proX Keyswitch BUS-2, Item no. 041470 is
in compliance with Directive 2014/53/EU.
The full text of the EU declaration can be downloaded from our homepage https://www.security.honeywell.de/ in the
service/download area.
Mounting and Operating Instructions proX Keyswitch BUS-2
12 V DC
10 V DC to 15 V DC
< 15 mA (average)
8 V DC
12K1 or 10k (programmable, MB-Secure 4k to 14k6)
±20%, ±30% or ±40% (programmable)
40 mA (active low)
40 mA (active low)
for IK2/proX1 and IK3/proX2 data carriers
125 kHz, <10 dBµA/m
Standard dimension A = 30 mm, A = 35 mm possible
-5 °C to +45 °C
-25 ° C to +70 ° C
II
IP 40
110 x 140 x 53 mm
traffic white (similar to RAL 9016)