Activated carbon filter change
Activated carbon filters bind odorous substances contained in kitchen fumes. Depen-
ding on the strain, these filters must be replaced or regenerated after 3 months at the
latest.
The activated carbon filter is mounted with a frame to the left and right of the fan modu-
le in the upper hood body. The metal grease filter must be removed before changing.
Then turn the locks by 90°, lift the activated carbon filter and pull it out diagonally to the
front. Pull the lateral filters to the middle and pull them out as well. The installation is
carried out in the reverse sequence.
Regeneration
Regeneration takes place in a preheated
oven (200°C) and takes 1-2 hours, de-
pending on the odorant load. Before re-
generation, clean the activated carbon fil-
ter with a damp cloth.
Attention Danger of burns!
Do not remove the activated carbon filter
from the oven until it has cooled down.
This can lead to unpleasant odours in the
oven !
Attention: Never use the pyrolysis func-
tion !
Important : The activated carbon filter
must not be cleaned wet. see separate
instructions "Activated Carbon".