12. Test run

12.1. The following phenomena do not represent faults.

Phenomenon
Indoor unit does not perform cooling
(heating) operation.
The auto vane rotates and begins to blow air
horizontally.
Fan setting changes during heating.
Fan stops during heating operation.
Fan does not stop while operation has been
stopped.
No setting of fan while start SW has been
turned on.
Indoor unit remote controller shows "H0"
or "PLEASE WAIT" indicator for about five
minutes when turning ON universal power
supply.
Drain pump does not stop when unit is
stopped.
Drain pump continues to operate while unit
has been stopped.
Indoor unit emits noise when switching from
heating to cooling and vice versa.
Immediately after startup, the indoor unit
emits the sound of the refrigerant flow.
Warm air comes from an indoor unit that is
not performing a heating operation.

13. Information on rating plate

Model
Unit combination
Refrigerant (R410A)
Allowable pressure (Ps)
Net weight
Model
Unit combination
Refrigerant (R410A)
Allowable pressure (Ps)
Net weight
Model
Unit combination
Refrigerant (R410A)
Allowable pressure (Ps)
Net weight
Model
Unit combination
Refrigerant (R410A)
Allowable pressure (Ps)
Net weight
Model
Unit combination
Refrigerant (R410A)
Allowable pressure (Ps)
Net weight
Model
Unit combination
Refrigerant (R410A)
Allowable pressure (Ps)
Net weight
Model
Unit combination
Refrigerant (R410A)
Allowable pressure (Ps)
Net weight
22
Display of remote controller
"Cooling (heating)" flashes
Normal display
Normal display
Defrost display
No lighting
Heat ready
"H0" or "PLEASE WAIT" flashes
Light out
Normal display
Normal display
Normal display
P200YJM-A
P250YJM-A
-
-
6.5kg
8.0kg
190kg
200kg
P500YSJM-A
P250
P250
8.0kg
8.0kg
200kg
200kg
P600YSJM-A
P350
P250
11.5kg
8.0kg
250kg
200kg
P700YSJM-A
P350
P350
11.5kg
11.5kg
250kg
250kg
P800YSJM-A
P800YSJM-A1
P450
P350
P400
11.8kg
11.5kg
11.5kg
290 kg
250 kg
250kg
P950YSJM-A
P400
P300
11.5kg
8.0kg
250kg
215kg
P1050YSJM-A
P400
P350
11.5kg
11.5kg
250kg
250kg
Cause
When another indoor unit is performing the heating (cooling) operation, the
cooling (heating) operation is not performed.
If air has been blowing downward for 1 hour during cooling, the unit may
automatically change to horizontal blowing with the control operation of the
auto vane. During defrosting or immediately after heating start-up/shut-down,
the auto vane automatically rotates to blow air horizontally for a short period
of time.
Ultra-low speed operation is commenced at thermostat OFF.
Light air automatically changes over to set value by time or piping temperature
at thermostat ON.
The fan is to stop during defrosting.
The fan is set to run for 1 minute after stopping to exhaust residual heat (only in
heating).
Ultra low-speed operation for 5 minutes after SW ON or until piping
temperature becomes 35°C, low speed operation for 2 minutes thereafter, and
then set notch is commenced (Hot adjust control).
The system is being started up.
Operate remote controller again after "H0" or "PLEASE WAIT" disappear.
After cooling operation stops, the unit continues to operate drain pump for
three minutes and then stops it.
Unit continues to operate drain pump if drainage is generated, even during a
stop.
This is a switching sound of the refrigerant circuit and does not imply a
problem.
Unstable flow of the refrigerant emits a sound. This is temporary and does not
imply a problem.
The LEV is slightly open to prevent refrigerant, of the indoor unit that is not
performing the heating operation, from being liquefied. This does not imply a
problem.
P300YJM-A
P350YJM-A
-
-
8.0kg
11.5kg
HP: 4.15MPa, LP: 2.21MPa
215kg
250kg
P500YSJM-A1
P300
P200
8.0kg
6.5kg
HP: 4.15MPa, LP: 2.21MPa
215kg
190kg
P600YSJM-A1
P300
P300
8.0kg
8.0kg
HP: 4.15MPa, LP: 2.21MPa
215kg
215kg
P700YSJM-A1
P400
P300
11.5kg
8.0kg
HP: 4.15MPa, LP: 2.21MPa
250kg
215kg
P850YSJM-A
P400
P450
11.5kg
11.8kg
HP: 4.15 MPa, LP: 2.21 MPa
250kg
290kg
P250
P400
8.0kg
11.5kg
HP: 4.15MPa, LP: 2.21MPa
200kg
250kg
P300
P400
8.0kg
11.5kg
HP: 4.15MPa, LP: 2.21MPa
215kg
250kg
P400YJM-A
P450YJM-A
-
-
11.5kg
11.8kg
250kg
290kg
P550YSJM-A
P300
P250
8.0kg
8.0kg
215kg
200kg
P650YSJM-A
P350
P300
11.5kg
8.0kg
250kg
215kg
P750YSJM-A
P400
P350
11.5kg
11.5kg
250kg
250kg
P900YSJM-A
P400
P450
P450
11.5kg
11.8kg
11.8kg
250kg
290kg
290kg
P1000YSJM-A
P300
P300
8.0kg
8.0kg
215kg
215kg
P1100YSJM-A
P350
P350
11.5kg
11.5kg
250kg
250kg