12. Guarantee

This instrument is covered by a 2 year guarantee from the
date of purchase. The guarantee is valid only on presenta-
tion of the guarantee card completed by the dealer (see
back) confirming date of purchase or the receipt.
• The guarantee covers the instrument. Batteries and
packaging are not included.
• Opening or altering the instrument invalidates the guarantee.
• The guarantee does not cover damage caused by
improper handling, discharged batteries, accidents or
non-compliance with the operating instructions.
Please contact Microlife-service.

13. Technical Specifications

Type:
Non Contact Thermometer NC 100
Measurement
Body Mode: 34.0-42.2 °C (93.2-108.0 °F)
range:
Object Mode: 0-100.0 °C (32-212.0 °F)
Resolution:
0.1 °C / °F
Measurement
Laboratory:
±0.2 °C, 36.0 ∼ 39.0 °C
accuracy:
(±0.4 °F, 96.8 ∼ 102.2 °F)
NC 100
Display:
Liquid Crystal Display, 4 digits plus
special icons
• The unit is turned ON and ready for the
Acoustic:
measurement: 1 short beep
• Complete the measurement:
1 long beep (1 sec.) if the reading is less
than 37.5 °C (99.4 °F), 10 short «beep»
sounds, if the reading is equal to or
greater than 37.5 °C (99.4 °F).
• System error or malfunction:
3 short «bi» sounds
• Auto-Display the last measured
Memory:
temperature
• 30 readings recall in the Memory Mode
• The display light will be GREEN for
Backlight:
4 seconds, when the unit is turned ON.
• The display light will be GREEN for
5 seconds, when a measurement is
completed with a reading less than
37.5 °C (99.4 °F).
• The display light will be RED for
5 seconds, when a measurement is
completed with a reading equal to or
higher than 37.5 °C (99.4 °F).
Operating
Body Mode: 16-40.0 °C (60.8-104.0 °F)
temperature:
Object Mode: 5-40.0 °C (41-104.0 °F)
Storage
-20 °C to +50 °C (-4 °F to 122 °F)
temperature:
15-95 % relative maximum humidity
Automatic
Approx. 1 minute after last measurement
Switch-off:
has been taken.
Battery:
2 x 1.5 V Batteries; size AAA
Dimensions: 150 x 40 x 39 mm
Weight:
81 g (with batteries), 56 g (w/o batteries)
Reference to
ASTM E1965;
standards:
IEC 60601-1; IEC 60601-1-2 (EMC)
This device complies with the requirements of the Medical
Device Directive 93/42/EEC.
Technical alterations reserved.
According to the Medical Product User Act a biennial tech-
nical inspection is recommended for professional users.
Please observe the applicable disposal regulations.

14. www.microlife.com

Detailed user information about our thermometers and
blood pressure monitors as well as services can be found
at www.microlife.com.