Herunterladen Inhalt Inhalt Diese Seite drucken

Agilent Technologies TPS-compact X3580-64000 Bedienungshandbuch Seite 293

Inhaltsverzeichnis

Werbung

The controller can answers with the following response types:
Response Type
Logic
Numeric
Alphanumeric
ACK
NACK
Unknown Window
Data Type Error
Out of Range
Win Disabled
TPS-compact User Manual / 87-901-010-01 (H)
Response
Response
Length
Value
1 byte
-
6 bytes
-
10 bytes
-
1 byte
(0x6)
1 byte
(0x15)
1 byte
(0x32)
1 byte
(0x33)
1 byte
(0x34)
1 byte
(0x35)
Technical Information
Window Protocol
Description
After a read instruction of a logic
window
After a read instruction of a numeric
window
After a read instruction of an
alphanumeric window
The command execution has been
successfully completed
The command execution has been
failed
The specified window in the
command is not a valid window
The data type specified in the
command (Logic, Numeric or
Alphanumeric) is not accorded with
the specified Window
The value expressed during a write
command is out of range value of
the specified window
The specified window is Read Only
or temporarily disabled (for example)
you can't write the Soft Start when
the Pump is running)
17
293/314

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis