9 PROBLEMS, CAUSES AND SOLUTIONS

WARNING
• Before undertaking any action, follow the instructions in the "Switching off" section. If it is not possible
to restore correct operation of the high pressure cleaner using the information in the table below, contact
a Skilled Technician.
PROBLEMS
By setting the switch (2)
to "1", the water cleaner
does not start.
Remember also what
mentioned in the note
of section "Interrupting
the use (Total Stop)"
T h e w a t e r c l e a n e r
vibrates a lot and is
noisy.
The water cleaner does
not reach the maximum
pressure.
Poor detergent suction. The nozzle-holding head (18) is in
No water comes out
from the nozzle (20).
The water cleaner stops
during the operation.
R o t at i n g t h e m a i n
switch (2), the motor
hums but does not start.
The water cleaner does
not supply hot water.
CAUSES
A safety device of the system
to which the water cleaner is
connected (fuse, differential
switch, etc.) has triggered.
The plug of the power supply
cable is not inserted correctly.
The water s uc tio n filte r/
gasket  (33) and/or the inner
water inlet filter is dirty.
The water supply is not enough. Check that the tap is completely opened
The nozzle-holding head (18) is in
low pressure position (Fig. 1-a).
The water nozzle (20) is worn.
low pressure position (Fig. 1-b).
The used detergent is too viscous. Use a detergent that is recommended by
Product missing in the tank.
Water missing.
Water nozzle clogged.
A safety device of the system
to which the water cleaner is
connected (fuse, differential
switch, etc.) has triggered.
The amperometric protection
device has cut in.
The electrical system and/or the
extension are not suitable.
The Diesel in the tank is below
the minimum level.
The Diesel filter is clogged.
SOLUTIONS
Reset the protection device.
In case of a new triggering, do not use
the water cleaner and apply to a Skilled
Technician.
Disconnect the plug from the socket and
reconnect it correctly.
Observe what mentioned in the section
"Routine maintenance" and "Special
maintenance" .
and that the capacity of the hydraulic
network conforms with what mentioned
in the section "Features and technical
specifications" .
Rotate the nozzle-holding head as shown
in Fig. 1-b.
Replace the nozzle according to what
mentioned in the section "Features and
technical specifications" .
Rotate the nozzle-holding head as shown
in Fig. 1-a.
the producer,by observing the thinning
indicated on the label.
Add product to the tank.
Check that the tap of the water network is
completely opened.
Clean and/or replace the nozzle according
to what mentioned in the section
"Features and technical specifications" .
Reset the protection device.
In case of a new triggering, do not use
the water cleaner and apply to a Skilled
Technician.
Observe what mentioned in the section
"Safety devices" .
Observe what mentioned in the section
"Checks and connection to mains
electricity supply" .
Add Diesel
Observe what mentioned in the section
"Special maintenance" .