Herunterladen Inhalt Inhalt Diese Seite drucken

CleanCraft HDR-H 54-15 Bedienungs- Und Wartungsanleitung Seite 26

Heisswasser-hochdruckreiniger
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 66
• Restart the water cleaner by setting the main switch (2) to "1".
Note: during this starting-up the water cleaner stops immediately after the starting pickup, because the
Total Stop device is activated.
• Rotate the temperature adjusting knob (27) in order to select the wished temperature.
• Operate the water cleaner, thus starting the washing operations; you only need to activate the lever (24)
of the water gun.
• The pressure value can be read from the pressure gauge (30).
• If you wish to shift from the operation with hot water to the one with cold water, set the temperature
adjusting knob (27) to "0".
CAUTION
• Periodically check the gas oil level in the tank and fill it before it empties completely.
• The burner starts to work only after approx. three seconds from the water gun opening and stops when
the water gun is closed or when the set temperature is reached.
5.4 Use with Detergents
WARNING
• The high pressure cleaner was designed to be used with the detergents recommended by the Manufacturer.
Use of other detergents or chemicals can affect the safety of the high pressure cleaner.
Never suck up liquids, which contain solvents, petrol, diluents, acetone and fuel oil, as these products are
highly inflammable, explosive and toxic when nebulized.
• Carefully read the instructions and warnings on the label of the detergent to be used.
• Store detergents in a safe place out of children's reach.
• Should detergent come into contact with your eyes, wash immediately with water. Contact a doctor without
delay and remember to take the container of detergent with you.
• If detergent is swallowed, do not provoke vomiting. Contact a doctor without delay and remember to take
the container of detergent with you.
• When filling the tank with detergent, take care not to spill any detergent on the high pressure cleaner. If
this should happen, wait at least 24 hours before using the high pressure cleaner so that any liquid, which
may have entered the appliance, can evaporate.
The recommended detergents, are over 90% biodegradable.
• Remove the plug (31) and by paying attention not to make the fluid overflow (we recommend to
use a funnel only for this operation), fill the tank (max. capacity of 4.5 l/1.2 US gal) by following the
recommendations relating to the batching that are reported on the detergent packaging; close the tank.
CAUTION
• During the filling/topping-up operations of the Detergent tank, pay attention not to confuse the
tanks. If you pour detergent into the Diesel tank by mistake, do not use the water cleaner and apply
to a Skilled Technician.
• As for the use mode, refer to the indications on the detergent packaging.
• Rotate the ring nut of the nozzle-holding head (18) as shown in Fig. 1-a and then activate the lever (24)
of the water gun and start to spray the detergent. Rotate the nozzle-holding ring nut (18) as shown
in Fig. 1-b to reset the high-pressure operation.
5.5 Interrupting Use (Total Stop)
Release the lever (24) on the cleaner gun and the water cleaner will automatically stop.
The water cleaner starts operating normally again when the lever on the cleaner gun is pressed again.
WARNING
• It is important to remember that the high pressure cleaner is still operational when it is in Total Stop mode.
Therefore, always put the main switch (2) in position "0", remove the plug from the power outlet, press the
lever (24) on the cleaner gun to eliminate any remaining pressure and lock the safety protection device (25)
(Fig. 1 - position S), before leaving it unattended, even for a short time.
26

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis