AVENTICS | Bus Coupler AES/Valve Driver AV, PROFIBUS DP | R412018135–BAL–001–AG
Conversion of the Valve System
PLC configuration key
12.5.5

Conversion documentation

After a conversion, the PLC configuration key printed on the right end plate is no longer valid.
Correct the PLC configuration key or cover it with a new label and write the new PLC
configuration key on the end plate.
Always document all changes to your configuration.
Mat. no.
After a conversion, the material number (MNR) on the right end plate is no longer valid.
Mark the material number so that it is clearly visible that the unit no longer corresponds
to its original condition on delivery.

12.6 Conversion of the I/O zone

12.6.1

Permissible configurations

No more than ten I/O modules may be connected to the bus coupler.
For further information on converting the I/O zone, see the system descriptions of the individual
I/O modules.
We recommend an expansion of the I/O modules starting from the left end of the valve system.
12.6.2
Conversion documentation
The PLC configuration key is printed on the top of the I/O modules.
Always document all changes to your configuration.

12.7 New PLC configuration for the valve system

Configuration error!
An incorrect valve system configuration can cause malfunctions in and damage to the overall
system.
The configuration may therefore only be carried out by an electrical specialist!
Observe the specifications of the system owner as well as any restrictions resulting from
the overall system.
Observe the documentation of your configuration program.
After converting the valve system, you need to configure the newly added components. Components
that are still in their original slots will be detected and do not require a new configuration.
If you have exchanged components without changing their order, you do not need to reconfigure
the valve system. All components will be recognized by the controller.
For the PLC configuration, proceed as described in section 5 "PLC Configuration of the Valve
System" on page 75.
NOTICE