Electronic lock

► To lock press [OUTon] and [OUToff] together for 1020 s
> Acknowledgement: LED status (yellow) inverted
► To unlock repeat procedure

Operation

Check whether the unit operates correctly Display by LEDs
Yellow LED on
Red LED on
Yellow LED flashes

Switch point compensation

Once the sensitivity setting has been carried out, the unit automatically compen-
sates for switch point drift
The red LED lights and the output FC "Function check output" switches as soon
as the limit of the switch point compensation is reached At this point the lens of
the unit and the prismatic reflector need to be cleaned (→ Maintenance).
After cleaning new programming of the unit is carried out automatically To do so,
no object is allowed in the beam

Maintenance

Keep the lens of the unit and the prismatic reflector free from contamination For
cleaning do not use any solvents or cleaning agents which could damage the
plastic
OUT output is switched
Limit of the switch point compensation reached:
eg unit out of alignment; lens / reflector dirty
FC output switched
2 Hz: internal fault
8 Hz: sensitivity setting incorrect
(OUT output is not switched)