10
User and installation manual HNS-M2
Flushing and rinsing
HNS – M2 steam generator has an option for an automatic flush and rinse cycle (Accessory: Automatic drain valve).
15 minutes after the steam generator has stopped or has been stopped, the electronic flush valve will open. After the
flush (takes 4 minutes) the steam generator will fill its tank again with cold water and flush it again (rinse). By
emptying the steam generator's tank straight after use, the product will gain a long life cycle even in areas where
water quality leaves room for improvement. Flushing the tank is not a substitute for a regular decalcification.
After flushing, the steam generator will shut down to stand-by mode until the next programme is initiated.
Safety valve installation
The safety valve is installed on the steam pipe with using
the provided ½" T connector.
A separate downpipe directly to a drain or to the floor is
installed on the safety valve. NOTE: Safety valve's
downpipe must not be connected to the steam generator's
draining pipe or the steam pipe.. Use the provided sealing
tape or similar sealing on the threads.
Image.
Safety valve and flushing valve
(Automatic drain valve) installed.

Cleaning the steam room

Rinse the seats and the floor with warm water after every use (do not use a pressure washer). Clean the seats
regularly with mild detergent. Use ethyl alcohol or dilutine. Never use abrasives, strongly alkaline detergents or
solvents to clean the steam room seats and walls. Contact the manufacturer if necessary.
It is important to clean the floor carefully all the way to the corners. Use hot water, a brush and floor detergent that
removes dirt and grease.
The product's warranty will be void if the steam generator has been incorrectly installed or it has been used
in a manner other than described in the user manual.
The warranty also expressly excludes operational faults if they are caused by hard water i.e. water with high
levels of chalk, or otherwise impure water.
The steam generator must be maintained as described in the user manual.

Steam generator in professional use

In addition to decalcification treatment, it is recommended to make a service plan for steam generators in daily use (6
hours or more). Service is recommended to be done 6 times a year and it is to include visual inspection of the heating
elements and the surface sensor, inspection and cleaning (lime accumulation) of the inner surface of the tank, and