Pull out the mains plug.
This will prevent danger of injury
from electric shock.
The appliance is supplied with the
textile ilter bag (
1. Attach the carrying handle
(2) irmly using the cross-head
screws (2a) supplied.
2. Attach the feet (7) and secure the
feet using the cross-head screws
(7a) supplied.
3. Insert the ilter:
-
Foam ilter for wet vacuuming
(
15),
-
Material ilter (
vacuuming,
-
Paper ilter bag (
Never vacuum without a ilter!
4. Place the motor housing (1) on
top of the dirt collector (6) and
close it
5. Connect the vacuum hose (13)
(bayonet ixing) and the acces-
sories.

Operation

Fully unwind the suction hose (
13) before commencing work.

Switching on/off

Connect the mains plug.
Switching on the vacuum:
On/off switch (
Switching off the vacuum:
On/off switch (
16) itted.
16) for dry
17).
with the clips (8).
3) in position "I".
3) in position "O".
GB

Nozzle usage

Floor nozzle (
tachment (
19):
for wet and dry vacuuming of smooth sur-
faces and itted carpets.
Floor nozzle (
attachment (
for wet and dry vacuuming of itted carpets
and for removing persistent dirt.
Press the clips on the right and left side
of the loor nozzle (
the insert attachment (
Mind that sensitive surfaces might
get scratched if the insert attach-
ment is not used.
Crevice nozzle (
for vacuuming gaps, corners and radiators.

Wet vacuuming

1. For wet vacuuming or to vacuum wa-
ter, it the foam ilter (15) to the ilter
basket (21).
To avoid tearing the foam ilter (15):
- Use only a dry ilter;
- Before inserting, twist the edge of
the ilter slightly and then roll it back.
2. Suctioning up (draining) water: place
the suction hose (
(
14) into the water tank and suc-
tion up the water.
3. Empty the waste container immediately
after vacuuming because it is not de-
signed to store liquids (see "Cleaning/
Maintenance").
Never reach into the water to
be suctioned up. Danger of
electric shock.
IE
NI
18) with insert at-
18) without insert
19):
18) and remove
19).
20):
13) on the handle