Herunterladen Inhalt Inhalt Diese Seite drucken

Leuze BPS 8 S M 100-xx Anleitung Seite 24

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
EN
Interface type
Baud rate
Data format (configurable)
Service interface (fixed data format)
Switching input / output
Degree of protection
VDE protection class
Housing
Weight without/with heating
Dimensions
Ambient temp. operation/storage
Rel. air humidity (non-condensing)
Vibration
Shock/continuous shock
Electromagnetic compatibility
Conformity
1) 3)
Certifications
1) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC
2) Can be configured using the BPS Configuration Tool software
3) These sensors shall be used with UL Listed Cable assemblies rated 30V, 0.5A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
24
2)
RS 232 (RS 485 in combination with
MA 8-xx, optional)
1200 ... 187500Bd
Data bits: 7, 8, 9
Parity: none, even, odd
Stop bits: 1, 2
RS 232, 9600Bd, 8 bit, no parity,
1 stop bit; <STX> data <CR>< LF>
1 switching input 5VDC
or
1 switching output 5 ... 30V, 20mA
IP 67
III or PELV
Diecast zinc
70g
See
2
0°C ... +40°C/-20°C ... +60°C
Max. 90%
IEC 60068-2-6, test Fc
IEC 60068-2-27, test Ea
EN 61000-6-2:2005+AC:2005,
EN 61000-6-3:2007+A1:2011+AC:2012
CE, CDRH
UL 60950-1, CSA C22.2 No.60950-1

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bps 8 s m 102-xx

Inhaltsverzeichnis