Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch CAM 847 Erstinbetriebnahme Seite 23

Prüfsatz für unit injektoren und unit pump
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
9. Connect the additional UI/UP PCB to the trigger
electronics using the supplied ribbon cables (x3).
Fig. 4:
Attaching the ribbon cables
10. Remove both covers (see Fig. 1, Pos. 6 and 7) from
the housing. The covers are no longer needed.
11. Install the two supplied connectors in the housing
with the code facing upwards.
X 5
X 6
X 7
X 8
X 9
X 1 0
Fig. 5:
Inserting the connectors
Robert Bosch GmbH
Structure | CAM 847 | 23
12. Carefully push the trigger PCB (Fig. 6, Pos. 3) onto
the spacers in the housing.
3
Fig. 6:
Installing the trigger PCB
13. Fasten the trigger PCB using the fastening screw
(Fig. 1, Pos. 4) and washer (Fig. 1, Pos. 5).
14. Plug all connecting cables into the PCB.
15. Connect all cables to the additional UI/UP PCB.
X 1
X 2
X 3
X 4
X 5
Fig. 7:
Plugging in the connectors
16. Put on the cover.
17. Secure the cover once more with the self-tapping
screws.
X 6
X 7
X 8
X 9
X 1 0
|
1 689 978 508
2011-12-03
en

Werbung

Inhaltsverzeichnis
loading