3 V/m 80 MHz
Radiated RF
to
IEC61000-4-3
2.5 GHz
Note 1: At 80 MHz to 800 MHz, the separation distance for the higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from
structures, objects and people.
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios,
a
amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the
electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured
field strength in the location in which the device is used exceeds the applicable RF compliance level above, the device should be
observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-
orienting or relocating the device.
Over frequency range 150kHz to 80MHz. For Resp field strength should be less than 1V/m.
b
Recommended separation distances between portable and mobile RF communications equipment and the device
The Health Monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The
customer or the user of the Health Monitor can help prevent electromagnetic interference by maintaining a minimum distance
between portable and mobile RF communications equipment (transmitters) and the monitor as recommended below, according to
the maximum output power of the communications equipment.
Rated max. output
power of transmitter
(W)
0.01
0.1
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be
estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter manufacturer.
Note 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from
structures, objects and people.
3 V/m 80 MHz
to
2.5 GHz
Separation distance according to frequency of the transmitter (m)
150 kHz - 80 MHz
=
d
1
2 .
P
0.12
0.38
1.20
3.80
12.00
Recommended separation distances:
80 MHz~800 MHz:
d
800MHz-2.5GHz:
=
d
Where, P is the maximum output power rating of the transmitter in
watts (W) according to the transmitter manufacturer and d is the
recommended separation distance in meters (m).
Field strengths from fixed RF transmitters, as determined by an
electromagnetic site survey
level in each frequency range
vicinity of equipment marked with the following symbol:
80
MHz
-
800
=
d
1
2 .
P
0.12
0.38
1.20
3.80
12.00
25
=
1
2 .
P
2
3 .
P
, should be less than the compliance
a
. Interference may occur in the
b
MHz
800 MHz - 2.5 GHz
=
d
2
3 .
0.23
0.73
2.30
7.30
23.00
P