2-3. Connecting the Measuring Unit

Note
Once the connection is made, the measuring unit is initialized for the MG40 series when the power supply
is connected and started. Use caution because aft er initialization is performed, the measuring unit can
only be used with the MG40 series.
1
Connect the measuring units to the measuring unit connector on the MG42 hub unit.
Note
Be sure to connect measuring units that are compatible with the MG42 hub unit.
2
Remove the cover of the interpolation box switch on the measuring unit.
3
Move the switch in the direction of the arrow.
...... Th is enables communication.
Note
Do not disconnect the measuring unit from the connector while power is on. Disconnecting the measuring
unit will cause a communication error, and the system will have to be restarted.
MG42
2. Installation and Connections
2-3
(E)