Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Installing The Guard Interface; Nly ) - Hartridge HB378 Bedienungs- Und Wartungshandbuch

Common rail-ausbausatz (avm2)
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 97
OPERATING & SERVICING MANUAL

2. Installation

SWITCH OFF THE 3-PHASE ISOLATOR BEFORE STARTING THE
INSTALLATION PROCEDURE.
2.1 Installing the Guard Interface Board (HB378 & Machine No. <2285 Only).
1. Remove the gland plates from the rear panel of the console (Item 1, Figure 2.1).
2. Fit the Guard Interface Board Assembly A182B006 in place of the gland plates, so that the EXT1
(9-way) and EXT2 (14-way) sockets protrude through the panel cutouts.
additional cables coming out of the gland plates (e.g. to a printer), these can be routed through
the slots in the new PCB bracket.
3. Connect the comms cable from the new PCB assembly to PC COM 1.
4. Remove the machine right hand top panel to access the electric cabinet / System Control Board.
5. Feed the remaining 2 cables from the new PCB assembly down through the base of the console
and into the electric box. Connect as shown in the tables below.
A: 2-Core Cable:
Wire Colour
B: Multi-core Cable:
Wire Colour
Green (See note 1)
Yellow (see note 1)
White (see note 2)
Brown (see note 2)
10
THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
Figure 2.1: Console Rear Panel
Function
White
0 Vac
Brown
110/132 Vac
Function
Violet
Screen
Blue
0 V
Red
18 V
128 ppr
128 ppr
DRIVE OK
STOP
HARTRIDGE LIMITED
If there were any
Connect To
AVM2 0V BUS
SCB2 PIN 115
Connect To
SCB2 PIN 197
SCB2 PIN 172
SCB2 PIN 198
-
SCB2 PIN 167
SCB2 PIN 26
-
HL024, Issue 7 (AT2672)